7
Sample Program
Table 7-4 Program Comments
Line
Description
Waits until the state is Talk test.
60:
Directs the user: Talk.
61:
Confirms PASS/FAIL of the voice loop-back test.
62-66:
The user input to the Tester from the PC to display the test results on the screen of the Tester.
Waits until the measurement is completed.
68:
Queries the measurement result of AP.
73:
Displays the measurement value and judgment result of AP in the status field.
74:
75:(-93:) For channel = 1 to 3
Queries the measurement result of ILP (Down)
77:
Displays the measurement value and judgment result of ILP(D) in the status field.
78:
Queries the measurement result of ILP (Up)
79:
Displays the measurement value and judgment result of ILP (U) in the status field.
80:
Queries the measurement result of MAX TX Power.
81:
Displays the measurement value and judgment result of MAX TX Power in the status field.
82:
Queries the measurement result of MIN TX Power.
83:
Displays the measurement value and judgment result of MIN TX Power in the status field.
84:
Queries the measurement result of Frequency Error.
85:
Displays the measurement value and judgment result of Frequency Error in the status field.
86:
Queries the measurement result of Multi-Code Rho.
87:
Displays the measurement value and judgment result of Multi-Code Rho in the status field.
88:
Queries the measurement result of Time Offset.
89:
Displays the measurement value and judgment result of Time Offset in the status field.
90:
Queries the measurement result of Sensitivity/BER.
91:
Displays the measurement value and judgment result of Sensitivity/BER in the status field.
92:
Displays Complete message in the status field.
94: