Page 2
If software is for use in the performance of a U.S. Government prime contract or sub- contract, Software is delivered and licensed as “Commercial computer soft- ware” as defined in DFAR 252.227-7014 defined in FAR 2.101(a) or as “Restricted N9360A Multi UE Tester GSM Programming Manual...
Preface Thank-you for purchasing the Agilent N9360A Global System for Mobile Communication (GSM) option. This is the GSM software for the N9360A Multi UE Tester. • Before using the tester, the user is advised to read this manual carefully to ensure correct usage and also to fully utilize the tester capability.
• Other product names and companies used herein are trademarks or registered trademarks of their respective companies or Agilent Technologies, Inc. For registered trademarks, the trademarks symbols ® and ™ are omitted in this manual. N9360A Multi UE Tester GSM Programming Manual...
Page 5
The N9360A-S01, N9360A-S02, N9360A-S03, N9360A-S04 are the RF shield box options which are intended to be used together with N9360A (GS8210) tester. Therefore as being an accessory of the N9360A, the RF shield box does not carry a separate CE marking.
Page 6
ICES/NMB-001:2004 This ISM device complies with Canadian ICES-001. Cet appareil ISM est confomre à la norme NMB-001 du Canada. Regulatory Information for Australia/New Zealand This ISM device complies with Australian/New Zealand AS/NZS CISPR11:2004 N9360A Multi UE Tester GSM Programming Manual...
Understanding common terms Standard Notation Command Syntax Overview of the Ethernet Interface Overview of the GP-IB Interface Overview of the RS-232C Serial Interface 4-10 Programming Guidelines 4-13 Typical Programming Flow for the Tester 4-13 N9360A Multi UE Tester GSM Programming Manual...
Page 8
Command Reference for Peak TX Power Measurement Screen 5-99 Command Reference for Burst Timing/Power Ramp Measurement Screen 5-100 Command Reference for Phase/Frequency Error Measurement Screen 5-104 Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen 5-114 viii N9360A Multi UE Tester GSM Programming Manual...
Page 9
TRIGger Subsystem 5-197 TRIGger Subsystem Command Reference 5-197 Programming Command Summary IEEE Common Commands Top Menu Commands Display Screen Initial Softkey Screen Configuration Screen System Configuration Screen Test Sequence : Test Sequence Screen N9360A Multi UE Tester GSM Programming Manual...
Page 10
6-42 Trigger Function 6-43 Sample Program Summary of Sample Programs Components of Window Functions Test Event Automatic Test Function Manual Test (GSM) function 7-10 Manual Test (GPRS) Function 7-13 TX Analyzer Function 7-16 N9360A Multi UE Tester GSM Programming Manual...
Page 15
TCH Channel Talk (Expanded version) Allowable Range 5-93 Table 5-23 The Lower Limit Value in GMSK, 8PSK 5-111 Table 5-24 The Upper Limit Value in GMSK, 8PSK 5-112 Table 5-25 RX Quality 5-115 Table 5-26 RX Level 5-116 N9360A Multi UE Tester GSM Programming Manual...
Page 16
Automatic Test [Stand-by]/[Measuring] Screen Command Summary 6-20 Table 6-13 Automatic Test RESults Command Summary 6-22 Table 6-14 Manual Test [Stand-by] Screen Command Summary 6-28 Table 6-15 Manual Test [Measuring] Screen Command Summary 6-29 N9360A Multi UE Tester GSM Programming Manual...
Page 17
Table 7-2 Status Display Functions Table 7-3 Functions for Sending and Receiving Data Table 7-4 Program Comments Table 7-5 Program Comments 7-11 Table 7-6 Program Comments 7-15 Table 7-7 Program Comments 7-17 N9360A Multi UE Tester GSM Programming Manual xvii...
Page 18
THIS PAGE IS INTENTIONALLY LEFT BLANK. xviii N9360A Multi UE Tester GSM Programming Manual...
Page 19
Legal Information Warranty Technology Licenses Restricted Rights Legend Service And Support Agilent On The Web Agilent By Phone Agilent Technologies...
Restricted Rights as defined in FAR 52.227-19(c)(1-2)(June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2)(November 1995), as applicable in any technical data. N9360A Multi UE Tester GSM Programming Manual...
WARNING notice until the indicated conditions are fully understood and met. NOTE denotes important information. It calls attention to a procedure, N O T E practice, condition or the like, which is essential to highlight. N9360A Multi UE Tester GSM Programming Manual...
Do not remove, damage or modify the warning label. General The protection provided by the N9360A system may be impaired if WA R N I N G the tester is used in a manner not specified by Agilent or the instructions on the display are not followed.
Do not turn off the Line switch on the rear panel of the Tester while C A U T I O N the LINE LED on the front panel of the Tester is lit in green. Otherwise, Tester failure may occur. N9360A Multi UE Tester GSM Programming Manual...
Equipment for Automated Test System Ethernet GP-IB RS-232C (Option E01) Connecting to Controller Ethernet GP-IB RS-232C This chapter describes a quick overview of how to set up an automated test system with the Agilent N9360A Multi UE Tester GSM Test Capability. Agilent Technologies...
• An RF cable to connect the RF signal from or to the mobile phone under test, the Antenna Coupler (Agilent N9360A-A02) to connect RF signal from or to the mobile phone to couple RF signal from or to the mobile phone.
• An RF cable to connect the RF signal from or to the mobile phone under test, the Antenna Coupler (Agilent N9360A-A02) to connect the RF signal from or to the mobile phone to couple the RF signal from or to the mobile phone.
Using an Option E02 The following equipment is required to configure an automated test system using the GP-IB interface: • The Agilent N9360A Multi UE Tester (with option E02). • A USB-GPIB Converter (option E02). • A system controller with the GP-IB interface.
RS-232C (Option E01) The following equipment is required to configure an automated test system using RS-232C interface: • The Agilent N9360A Multi UE Tester (with option E01). • A system controller with the RS-232C interface. • An RS-232C null modem cable.
RS-232C null modem cable and the 25-pin male connector to connect the controller (PC) and the Tester. Ignore the control lines (CTS, DSR, DCD and RI) status with the controller. N O T E N9360A Multi UE Tester GSM Programming Manual...
Preparing for Use An example of connection of these cable and adapter are shown Figure 3-5 as follows. Figure 3-5 RS-232C Cable and Adapter connection N9360A Multi UE Tester GSM Programming Manual...
Page 34
Preparing for Use THIS PAGE IS INTENTIONALLY LEFT BLANK N9360A Multi UE Tester GSM Programming Manual...
Page 35
4-13 Typical Programming Flow for the Tester 4-13 Using the Status Registers 4-16 Why Would You Use the Status Registers? 4-16 Status Register System 4-19 Error Messages 4-23 This chapter contains a brief overview of the programming commands. Agilent Technologies...
But the bracketed words <program message> indicate a precisely defined element of the commands. If you need them, you can find the exact definitions of words such as <program message> in a syntax diagram. N9360A Multi UE Tester GSM Programming Manual...
• Lower-case lettering indicates that the lower-case portion of the command is optional (long form); it can either be included with the upper-case portion of the command or omitted. For example, in the command :FREQuency, both :FREQ and :FREQUENCY is correct. N9360A Multi UE Tester GSM Programming Manual...
Page 38
• << (continue) indicates the line does not end and continue to the next line. For example, ABC << Is same as follows ABC DEF In addition, all commands, parameters and mark to use in the programming are the ASCII code characters. N9360A Multi UE Tester GSM Programming Manual...
The TCP port number is 10123 (fixed). User cannot use the address from 192.168.1.1 to 192.168.1.255 as it is already used by the Tester. Refer to the following procedure to set the Ethernet configuration. N9360A Multi UE Tester GSM Programming Manual...
Terminator input field is set on this screen. Figure 4-1 [Network Setting] Screen (Ethernet Interface) Step 2 On the [configuration] screen, press the Network Setting softkeys to obtain the [Network Setting] screen. Set the Ethernet setting parameters on this screen. N9360A Multi UE Tester GSM Programming Manual...
The terminator inputted to tester is LF (for GPIB option E02) The terminator inputted to tester is CR+LF (for GPIB option If EOI is set to , the terminator is not transmitted. Refer to the following procedure to set the GP-IB configuration. N9360A Multi UE Tester GSM Programming Manual...
On the [Top Menu] screen or the [Initial] screen, press the Config softkey to obtain the [Configuration] screen. Figure 4-3 [Configuration] Screen (GP-IB Interface) Step 2 Confirm that the GP-IB configurations are correctly set. Step 3 Reboot the Tester to activate the configuration. N9360A Multi UE Tester GSM Programming Manual...
The terminator inputted to tester is LF (for GPIB option E02) The terminator inputted to tester is CR+LF (for GPIB option Refer to the following procedure to set the serial port configuration. 4-10 N9360A Multi UE Tester GSM Programming Manual...
Config softkey to obtain the [Configuration] screen. Figure 4-4 [Configuration] Screen (RS-232C Interface) Step 2 Confirm that the Serial Port configurations are correctly set. Step 3 Reboot the Tester to activate the configuration. N9360A Multi UE Tester GSM Programming Manual 4-11...
Page 46
• Overrun error: A receiver buffer overflows, and received data is lost. This error is most commonly caused by too fast communication speed (Baud Rate). In this case, reduce the communication speed (Baud Rate). 4-12 N9360A Multi UE Tester GSM Programming Manual...
GP-IB and Ethernet interface. < Send Command to the Tester> *RST Step 2 Select the GSM application, and display the [Initial] screen of the GSM system. < Send Command to the Tester> APPL:GSM N9360A Multi UE Tester GSM Programming Manual 4-13...
Page 48
<Send Query Command to the Tester> TEST:MAN:SIGN:STAT? If the Response is not , re send the query. Else, proceed to the next step. Step 7 Start the measurement. <Send Command to the Tester> TRIG:IMM 4-14 N9360A Multi UE Tester GSM Programming Manual...
Page 49
Start the BS Release, for example: <Send Command to the Tester> TEST:MAN:BSR <Send Query Command to the Tester> TEST:MAN:SIGN:STAT? If the Response is not , re send the query. Else, complete the test. N9360A Multi UE Tester GSM Programming Manual 4-15...
Determine which register contains the bit that reports the condition. Send the query that reads that register. Examine the bit to see if the condition has changed. 4-16 N9360A Multi UE Tester GSM Programming Manual...
Page 51
The query stops any new commands from being processed until the current processing is complete, then returns • *STB? (status byte) queries the value of the status byte register without erasing its contents. N9360A Multi UE Tester GSM Programming Manual 4-17...
The result of a query is evaluated in a similar way. If the command *STB? returns a decimal value of 140 (= 128 + 8 + 4), then the are set to bit 7 bit 3 bit 2 4-18 N9360A Multi UE Tester GSM Programming Manual...
Tester. Figure 4-6 Overall Status Byte Register System Each of these status registers is explained in detail in the following sections. N9360A Multi UE Tester GSM Programming Manual 4-19...
For example, if the bit 5 and bit 4 are set to , the decimal sum of these 2 bits is 48 (32 plus 16) see Figure 4-5. So the decimal value 48 is returned. 4-20 N9360A Multi UE Tester GSM Programming Manual...
. For example, if the bit 7 and bit 3 are set to the decimal sum of these 2 bits is 136 (128 plus 8) see Figure 4-5. So the decimal value 136 is returned. N9360A Multi UE Tester GSM Programming Manual 4-21...
5 of the Status Byte Register, bit 7 and 5 are set to *ESE 160 command (128 plus 32). See Figure 4-5. The query command *ESE? returns the decimal value of the sum of the bits previously set by with the *ESE <int> command. 4-22 N9360A Multi UE Tester GSM Programming Manual...
Command error due to character data is too long –200 Execution error due to an invalid command –222 Execution error due to data that is out of range –350 Device dependent error due to a queue overflow N9360A Multi UE Tester GSM Programming Manual 4-23...
Page 58
Programming Command Guideline THIS PAGE IS INTENTIONALLY LEFT BLANK. 4-24 N9360A Multi UE Tester GSM Programming Manual...
This chapter describes all commands of syntaxes, parameters, and response. Some commands are valid only for corresponding mode (GSM, GPRS, and EGPRS). Be sure that the mode is set correctly before executing each command. The Option G03 should be installed for using the EGPRS function. Agilent Technologies...
This command sets or queries the OPC bit (bit0) of the Standard Event Status Register (SESR). The query command returns 1. Clear Status *CLS This command initializes the Status Byte Register (STBR) and the Standard Event Status Register (SESR). N9360A Multi UE Tester GSM Programming Manual...
Page 61
This command sets or queries a value of the Standard Event Status Enable Register (SESER). The allowable range is from 0 to 255. For detailed information, refer to Standard Event Status Enable Register page 4-22. N9360A Multi UE Tester GSM Programming Manual...
Page 62
This query command returns a value of the option numbers installed in the Tester. Selftest Result Query *TST? This query command returns the result of self diagnosis with integer value of 0 (Normal) or 1 (Abnormal). N9360A Multi UE Tester GSM Programming Manual...
0. This query command returns the panel keys setting with integer value of 1 or 0. Option Code OPTion:SET <string> This command installs an option code to the Tester with 16 ASCII characters. N9360A Multi UE Tester GSM Programming Manual...
The parameters of the serial interface and the GP-IB interface are set with N O T E the User Interface (Screen). The parameters of the ethernet interface are able to set by a program. N9360A Multi UE Tester GSM Programming Manual...
Page 65
This command selects the [Update Flash] screen. This is available only when the Option C03 is installed in the Tester. Application Type DISPlay:APPLication? This command returns the type of application currently in operation. N9360A Multi UE Tester GSM Programming Manual...
Application Select Commands Application APPLication:GSM This command selects the GSM Function Tester application (N9360A-FUNC) and displays the [Initial] screen of the GSM mode. G00 option is required to install in the Tester. APPLication:WCDMA This command selects the W-CDMA Function Tester application (N9360A-FUNC) and displays the [Initial] screen of the W-CDMA mode.
ON, there is beep for each step of operation. If this is set to OFF, beep is suppressed except for some errors and warnings. At preset, this is set to 1. This query command returns the beep setting with integer value of 1 or 0. N9360A Multi UE Tester GSM Programming Manual...
Page 68
0 to 59. This query command returns the time of the clock in the Tester with <int HH> and <int MM>. The range of these values is same as that of the command parameter. 5-10 N9360A Multi UE Tester GSM Programming Manual...
Page 69
This query command returns the settings of application name and the duration time. When this command is set to NONE, it returns 0. RF-CPU Revision CONFigure:REVision:RF? This query command returns the firmware revision of RF-CPU with a string xx.xx. N9360A Multi UE Tester GSM Programming Manual 5-11...
Tester uses them internally. <int> defines the subnet mask address. The value of <int> is in the CIDR format, ranging from 1 to 31. This query command returns the settings of IP address and subnet mask address. 5-12 N9360A Multi UE Tester GSM Programming Manual...
Page 71
Setting 1 to Setting 5. The parameter is ACT (for enabling) or NONE (for disabling). <string 1> specifies the Host/Net address. When <enum 2> is set to NONE, <string 1> N9360A Multi UE Tester GSM Programming Manual 5-13...
192.168.1.1 to 192.168.1.255 are unavailable to use. 1 to 31 1.0.0.0 to 223.255.255.255 (Subnet (Net specifying address) mask value) 192.168.1.0 to 192.168.1.255 are unavailable to use. NONE These query commands return the set values. 5-14 N9360A Multi UE Tester GSM Programming Manual...
• <string 2> (4 letters) is the result code of update. If update is a failure, it is equivalent to the error code. If update is a success, it is 0000. • USB|HDD|SERVER is the update type. N9360A Multi UE Tester GSM Programming Manual 5-15...
Page 74
UPDAte:HISTory? is 0. At preset, this is set to 1. This query command returns the read-out starting position of the history of update result setting with integer. The range of this values is same as that of the command parameter. 5-16 N9360A Multi UE Tester GSM Programming Manual...
Page 75
223.255.255.255. At preset, this is set to 0.0.0.0. This query command returns the IP address of ftp server for SERVER update. The range of this values is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-17...
Page 76
The format of archive file is FUNC_F.xx.xx or FUNC_F.xx.xx.yy (x: numeric character, y: alphanumeric character). It returns ?.??.?? if the tester is no recognized archive file. 5-18 N9360A Multi UE Tester GSM Programming Manual...
Page 77
This query command returns the version of the top menu which is installed in the tester. The format of revision is MENU_M.xx.xx or MENU_M.xx.xx.yy (x: numeric character, y: alphanumeric character). It returns ?.??.?? if the tester is no recognized archive file. N9360A Multi UE Tester GSM Programming Manual 5-19...
Page 78
This is effective only for W00 option installed tester. The format of revision is W00_W.xx.xx or W00_W.xx.xx.yy (x: numeric character, y: alphanumeric character). It returns ?.??.?? if the tester is no recognized archive file. 5-20 N9360A Multi UE Tester GSM Programming Manual...
ROM which is installed in the tester. The format of revision is MC1X.xx.xx or MC1X.xx.xx.yy (x: numeric character, y: alphanumeric character). It returns ?.??.?? if the tester is no recognized archive file. N9360A Multi UE Tester GSM Programming Manual 5-21...
Page 80
ROM which is installed in the tester. The format of revision is EVDO.xx.xx or EVDO.xx.xx.yy (x: numeric character, y: alphanumeric character). It returns ?.??.?? if the tester is no recognized archive file. 5-22 N9360A Multi UE Tester GSM Programming Manual...
CONF:COND:LIM [Configuration: Test Condition (Limit)] screen [Configuration: Test Condition (BA Table)] screen CONF:COND:BA [Configuration: Test Sequence] screen CONF:SEQ [Configuration: File Management] screen CONF:FILE [Configuration: Network Setting] screen CONF:NET The other screen ELSE N9360A Multi UE Tester GSM Programming Manual 5-23...
Page 82
TRACk by this command or pressing the soft key [Local]. At preset, this is set to TRACk. This query command returns the display mode (FAST or TRACk) setting with strings. 5-24 N9360A Multi UE Tester GSM Programming Manual...
This command selects the Automatic Test [Phase Error/Frequency Error] screen. The parameter specifies the Channel Number. Sensitivity/RX Quality/RX Level DISPlay:AUTO:SENSitivity 1|2|3|4|5|6 This command selects the Automatic Test [Sensitivity/RX Quality/RX Level] screen. The parameter specifies the Channel Number. N9360A Multi UE Tester GSM Programming Manual 5-25...
DISPlay:MANual:SENSitivity This command selects the Manual Test [Sensitivity/RX Quality/RX Level] screen. Spectrum Monitor DISPlay:MANual:SMONitor This command selects the Manual Test [Spectrum Monitor] screen. DISPlay:MANual:SMS This command selects the Manual Test [SMS] screen. 5-26 N9360A Multi UE Tester GSM Programming Manual...
Tester. The parameters for the serial andGP-IB are manually specifiable. N O T E The Ethernet parameters are specifiable in the program. 5-28 N9360A Multi UE Tester GSM Programming Manual...
Page 87
HDD or a USB memory device. Also, these files are recalled or deleted from the HDD or the USB memory device. N9360A Multi UE Tester GSM Programming Manual 5-29...
Page 88
Programming Command Reference Network Setting Screen DISPlay:CONFigure:NETwork This command selects the [Configuration: Network Setting] screen. 5-30 N9360A Multi UE Tester GSM Programming Manual...
This command selects the target system of operation. Selecting WCDMA opens the W-CDMA System Setting screen. Likewise, GSM and CDMA2000 open the GSM System Setting screen and the CDMA2000 System Setting screen, respectively. N9360A Multi UE Tester GSM Programming Manual 5-31...
This query command returns the date of the calendar in the Tester by <int YYYY>, <int MM> and <int DD>. The range of these values is same as that of the command parameter. 5-32 N9360A Multi UE Tester GSM Programming Manual...
Page 91
PMG800 and USB Memory. At preset, this is set to USBMemory.PMG800. This query command returns the output device of the Print Screen with strings. Log Output CONFigure:LOG:DEBUG:SAVE This command saves the debugging log. N9360A Multi UE Tester GSM Programming Manual 5-33...
This command selects a Sequence Number. The sequence number selected here applies to the commands that relate to sequence. The default value is 1. This query command returns the selected Sequence Number with integer value of 1 or 2. 5-34 N9360A Multi UE Tester GSM Programming Manual...
5-37 changes synchronously. This query command returns the set channel number of the Broadcast Control Channel with integer. The range of the value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-35...
Channel Number. The allowable range and preset values are as follows: Table 5-4 TCH Channel Talk (Expanded version) Allowable Range Radio System Traffic Channel Number GSM850 128 to 251 GSM900 955 to 1023 DCS1800 512 to 885 PCS1900 512 to 810 5-36 N9360A Multi UE Tester GSM Programming Manual...
5-35 changes synchronously. This query command returns the set frequency of the Broadcast Control Channel with integer. The range of the value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-37...
This command sets the Traffic Channel (TCH) frequency of Talk test for arbitrary radio system. <enum> is the Radio System Channel Frequency, <int> is the Channel Number of the Traffic Channel Frequency. The allowable range and preset values are as follows. 5-38 N9360A Multi UE Tester GSM Programming Manual...
Channel for Talk Test with integer. The range of the value is same as that of the command parameter. Measurement Test TCH Channel CONFigure:SEQuence:VARiable:TCH:CHANnel1 <int> CONFigure:SEQuence:VARiable:TCH:CHANnel1? CONFigure:SEQuence:VARiable:TCH:CHANnel2 <int> CONFigure:SEQuence:VARiable:TCH:CHANnel2? CONFigure:SEQuence:VARiable:TCH:CHANnel3 <int> CONFigure:SEQuence:VARiable:TCH:CHANnel3? CONFigure:SEQuence:VARiable:TCH:CHANnel4 <int> CONFigure:SEQuence:VARiable:TCH:CHANnel4? CONFigure:SEQuence:VARiable:TCH:CHANnel5 <int> CONFigure:SEQuence:VARiable:TCH:CHANnel5? N9360A Multi UE Tester GSM Programming Manual 5-39...
Traffic Channel for measurement test with integer. The range of the value is same as that of the command parameter. CONFigure:SEQuence:VARiable:TCH:CHANnel1:EXPand <enum>, <int> CONFigure:SEQuence:VARiable:TCH:CHANnel1:EXPand? CONFigure:SEQuence:VARiable:TCH:CHANnel2:EXPand <enum>, <int> CONFigure:SEQuence:VARiable:TCH:CHANnel2:EXPand? CONFigure:SEQuence:VARiable:TCH:CHANnel3:EXPand <enum>, <int> CONFigure:SEQuence:VARiable:TCH:CHANnel3:EXPand? 5-40 N9360A Multi UE Tester GSM Programming Manual...
128 to 251 GSM900 955 to 1023, 0 to 124 DCS1800 512 to 885 PCS1900 512 to 810 The preset values of radio system and frequency are GSM900 and 890200000 [Hz] respectively. N9360A Multi UE Tester GSM Programming Manual 5-41...
Page 100
These query commands return the set of the Peak TX Power test at High, Medium and Low power ranges with integer. The meaning of the return value is same as the parameter of the command parameter. 5-42 N9360A Multi UE Tester GSM Programming Manual...
Page 101
The set of each bit is 1 for Run and 0 for — (skip). At preset, this is set to 63. This query command returns the set of the Burst Timing test with integer. The meaning of the return value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-43...
Page 102
The set of each bit is 1 for Run and 0 for — (skip). At preset, this is set to 63. This query command returns the set of the Power Ramp test with integer. The meaning of the return value is same as that of the command parameter. 5-44 N9360A Multi UE Tester GSM Programming Manual...
Page 103
The set of each bit is 1 for Run and 0 for — (skip). At preset, this is set to 63. This query command returns the set of RMS Phase Error test with integer. The meaning of the return value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-45...
Page 104
The set of each bit is 1 for Run and 0 for — (skip). At preset, this is set to 63. This query command returns the set of Peak Phase Error test with integer. The meaning of the return value is same as that of the command parameter. 5-46 N9360A Multi UE Tester GSM Programming Manual...
Page 105
The set of each bit is 1 for Run and 0 for — (skip). At preset, this is set to 63. This query command returns the set of Frequency Error test with integer. The meaning of the return value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-47...
Page 106
The set of each bit is 1 for Run and 0 for — (skip). At preset, this is set to 63. This query command returns the set of BER Sensitivity test with integer. The meaning of the return value is same as that of the command parameter. 5-48 N9360A Multi UE Tester GSM Programming Manual...
Page 107
The set of each bit is 1 for Run and 0 for — (skip). At preset, this is set to 63. This query command returns the set of FER Sensitivity test with integer. The meaning of the return value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-49...
Page 108
The set of each bit is 1 for Run and 0 for — (skip). At preset, this is set to 63. This query command returns the set of RX Quality test with integer. The meaning of the return value is same as that of the command parameter. 5-50 N9360A Multi UE Tester GSM Programming Manual...
Page 109
The set of each bit is 1 for Run and 0 for — (skip). At preset, this is set to 63. This query command returns the set of RX Level test with integer. The meaning of the return value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-51...
Page 110
These six query commands return the set of the RF input path losses at each channel with real. The range of the values is same as that of the command parameter. Each value is separated by a comma. 5-52 N9360A Multi UE Tester GSM Programming Manual...
Page 111
These six query commands return the set of the RF output path losses at each channel with real. The range of the values is same as that of the command parameter. Each value is separated by a comma. N9360A Multi UE Tester GSM Programming Manual 5-53...
Page 112
1. This query command returns the set of first call test by integer value of 1 or 0. The meaning of the return value is same as that of the command parameter. 5-54 N9360A Multi UE Tester GSM Programming Manual...
1. This query command returns the set of RF test with integer value of 1 or 0. The meaning of the return value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-55...
Page 114
The parameter is MS or BS. At preset, this is set to BS. This query command returns the set of second caller with string of MS or BS. The meaning of the return value is same as that of the command parameter. 5-56 N9360A Multi UE Tester GSM Programming Manual...
Page 115
Sequence Number 1 is selected. The query command returns sets 3GPP System with integer. The range of the value is the same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-57...
This command sets the mode type to STD (GSM), GPRS or EGPRS. At preset, this is set to STD. This query command returns the mode setting by strings of STD, GPRS or EGPRS. 5-58 N9360A Multi UE Tester GSM Programming Manual...
Page 117
0 to 99. At preset, this is set to 1. This query command returns the set Mobile Network Code with integer. The range of the value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-59...
Page 118
2 to 9. At preset, this is set to 2. This query command returns the set number of multiframes with integer. The range of the value is same as that of the command parameter. 5-60 N9360A Multi UE Tester GSM Programming Manual...
1 (+30 dBm), 2 (+24 dBm), 3 (+33 dBm) 1 (+30 dBm) This query command returns the set MS power class with integer. The range of the value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-61...
* Values are in the order of High, Medium, and Low ranges. This query command returns the set Power Control Level with integer. The range of the value is same as that of the command parameter. 5-62 N9360A Multi UE Tester GSM Programming Manual...
Page 121
-50.0 dBm in 0.1 steps. At preset, this is set to -50.0 dBm. This query command returns the set amplitude of output signal with real. The range of the value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-63...
Page 122
BER (GSM Mode, Test Mode A) CONFigure:CONDition:SENSitivity:FRAMe <int> CONFigure:CONDition:SENSitivity:FRAMe? FAST BER (GSM Mode, Test Mode C) CONFigure:CONDition:SENSitivity:FRAMe:BERFast <int> CONFigure:CONDition:SENSitivity:FRAMe:BERFast? BER (GPRS Mode, Test Mode B) CONFigure:CONDition:SENSitivity:FRAMe:BERGprs <int> CONFigure:CONDition:SENSitivity:FRAMe:BERGprs? BLER (GPRS/EGPRS Test Mode ACK) CONFigure:CONDition:SENSitivity:FRAMe:BLER <int> CONFigure:CONDition:SENSitivity:FRAMe:BLER? 5-64 N9360A Multi UE Tester GSM Programming Manual...
Page 123
MID or LONG. At preset, this is set to MID. This query command returns the set loopback delay with strings of SHORT, MID or LONG. This command is valid when the GSM mode is set to GSM. N O T E N9360A Multi UE Tester GSM Programming Manual 5-65...
Page 124
This command sets the EGPRS Puncturing Scheme. The allowable range is P1, P2, and P3. At preset, this is set to P1. This command is valid when the GSM mode is set to EGPRS. N O T E 5-66 N9360A Multi UE Tester GSM Programming Manual...
Page 125
The allowable range is from 0 to 9. At preset, this is set to 0. This query command returns the set location update delay with integer. The range of the value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-67...
Page 126
N O T E Power Control Level (Limit) CONFigure:CONDition:LIMit:TXPower:PLEVel <int> CONFigure:CONDition:LIMit:TXPower:PLEVel? This command sets the value of Peak TX Power for each radio system set by the Radio System command described on page 5-34. 5-68 N9360A Multi UE Tester GSM Programming Manual...
This query command returns the set power control level with integer and low and high limits for Peak TX Power test with real separated by a comma. The range is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-69...
Page 128
Peak Phase Error test with real. The range is same as that of the command parameter. This command is invalid when EGPRS 8-PSK is selected. N O T E 5-70 N9360A Multi UE Tester GSM Programming Manual...
Page 129
This command sets the low and high limits for RX Level tests for each radio system set by the Radio System command described page 5-34. The parameters and the preset values are shown in the following tables: N9360A Multi UE Tester GSM Programming Manual 5-71...
Class II (GSM Mode, Test Mode A) CONFigure:CONDition:LIMit:BER:II <real HI> CONFigure:CONDition:LIMit:BER:II? Fast BER (GSM Mode, Test Mode C) CONFigure:CONDition:LIMit:FBER <real HI> CONFigure:CONDition:LIMit:FBER? BER (GPRS mode, Test Mode B) CONFigure:CONDition:LIMit:BERGprs <real HI> CONFigure:CONDition:LIMit:BERGprs? 5-72 N9360A Multi UE Tester GSM Programming Manual...
Page 131
The range is same as that of the command parameter. If the GSM mode is set to GPRS or EGPRS in Manual Test mode, N O T E measurement cannot be executed. N9360A Multi UE Tester GSM Programming Manual 5-73...
Page 132
0.00 to 99.99 (%) in 0.01 steps. The preset value of RMS, PEAK, and Ninetyfive is set to 9.00, 30.00 and 15.00 respectively. This command is valid when the GSM mode is set to EGPRS. N O T E 5-74 N9360A Multi UE Tester GSM Programming Manual...
Page 133
System that is being selected. The allowable range is from -99.9 to 0.0 (dBm). At preset, this is set to -15.0 (dBm). This command is valid when the GSM mode is set to EGPRS. N O T E N9360A Multi UE Tester GSM Programming Manual 5-75...
Page 134
At preset, this is set to GMSK, -15.0. This query command returns modulation type and high limit. Thise command is valid at corresponding GSM mode (GSM, GPRS, N O T E EGPRS) 5-76 N9360A Multi UE Tester GSM Programming Manual...
Page 135
PCS1900. The parameter is NARRow or ELaxed. At preset, this is set to NARRow. If RELaxed is set, the template is selected same one for DCS1800. This setting is initialized to NARRow at power on. N9360A Multi UE Tester GSM Programming Manual 5-77...
0.1 steps. At preset, it is set to 0.0 (dB). This query command returns the loss setting between a mobile phone and the Tester with real value. The range of the values is same as that of command parameter. 5-78 N9360A Multi UE Tester GSM Programming Manual...
OFF | BCCH | 955 to 1023 | 0 BCCH to 124 DCS1800 1 to 16 OFF | BCCH | 512 to 885 BCCH PCS1900 1 to 16 OFF | BCCH | 512 to 810 BCCH N9360A Multi UE Tester GSM Programming Manual 5-79...
1023 | 0 to 124 0 to 124 DCS1800 OFF | BCCH | 512 to OFF | 512 to 885 BCCH PCS1900 OFF | BCCH | 512 to OFF | 512 to 810 BCCH 5-80 N9360A Multi UE Tester GSM Programming Manual...
CONFigure:FILE:DELete <string FILENAME> This command deletes the test setup file specified by FILENAME from the HDD or a USB memory device. FILENAME accepts up to 8 alphanumeric characters. FILENAME is a double quoted string. N9360A Multi UE Tester GSM Programming Manual 5-81...
Page 140
This query command returns the set the number of the setup files. The range of the value is same as that of the command parameter. Files List Number CONFigure:FILE:LIST:NUMber? This query command returns the total number of setup files. 5-82 N9360A Multi UE Tester GSM Programming Manual...
Page 141
CONFigure:FILE:LIST:SHOrt? This query command returns a list of all setup files. The return format is <string TOTAL>, <string FILENO1>, <string FILENAME1>, ...<string FILENOn> and <string FILENAMEn>. The FILENAME is double quoted strings. N9360A Multi UE Tester GSM Programming Manual 5-83...
Page 142
File System CONFigure:FILE:SYSTem GSM|WCDMA|MULTI CONFigure:FILE:SYSTem? This command selects the file system from MULTI, GSM and WCDMA. At preset, this is set to MULTI. This query command returns the set file system with <enum>. 5-84 N9360A Multi UE Tester GSM Programming Manual...
Executing this command does not reflect the result on the tester, yet.? The result is reflected on the tester as CONFigure:NETwork:APPLy:ADDRess is implemented. Query of this command obtains the IP Address and subnet mask address (a value in CIDR format). N9360A Multi UE Tester GSM Programming Manual 5-85...
Page 144
Query of this command obtains the address of the Default Gateway being set. If NONE is selected for the Default Gateway address, the value of <enum> alone is returned. Gateway CONFigure:NETwork:GATEway:SET1 <enum1>,<string1>,<enum2>,<string2> CONFigure:NETwork:GATEway:SET1? CONFigure:NETwork:GATEway:SET2 <enum1>,<string1>,<enum2>,<string2> CONFigure:NETwork:GATEway:SET2? CONFigure:NETwork:GATEway:SET3 <enum1>,<string1>,<enum2>,<string2> CONFigure:NETwork:GATEway:SET3? 5-86 N9360A Multi UE Tester GSM Programming Manual...
Page 145
1 to 31. <string2> specifies the Gateway address. Executing this command does not reflect the result on the tester, yet. The result is reflected on the tester as CONFigure:NETwork:APPLy:ADDRess is implemented. Following lists the effective setting range. N9360A Multi UE Tester GSM Programming Manual 5-87...
1.0.0.1-223.255.255.255 Query of this command obtains the set value of the Gateway being specified. When NONE is selected from the enable/disable of the Gateway address, it returns the value of <enum1> alone. 5-88 N9360A Multi UE Tester GSM Programming Manual...
0 to 124, 955 to 1023 DCS1800 512 to 885 PCS1900 512 to 810 This query command returns the set Broadcast Control Channel number with integer. The range is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-89...
1 respectively. This query command returns the set channel number of the Traffic Channel for Talk Test with integer. The range of the value is the same as that of the command parameter. 5-90 N9360A Multi UE Tester GSM Programming Manual...
Page 149
Query of this command returns the screen mode currently selected in the character stings of the SIMPlified, DETailed, or VALue. Measurement TCH Variable TESTs:AUTO:VARiable:TCH:CHANnel1 <int> TESTs:AUTO:VARiable:TCH:CHANnel1? TESTs:AUTO:VARiable:TCH:CHANnel2 <int> TESTs:AUTO:VARiable:TCH:CHANnel2? TESTs:AUTO:VARiable:TCH:CHANnel3 <int> TESTs:AUTO:VARiable:TCH:CHANnel3? N9360A Multi UE Tester GSM Programming Manual 5-91...
Traffic Channel number for the measurement test with integer. The range is same as that of the command parameter. TESTs:AUTO:VARiable:TCH:CHANnel1:EXPand <enum>, <int> TESTs:AUTO:VARiable:TCH:CHANnel1:EXPand? TESTs:AUTO:VARiable:TCH:CHANnel2:EXPand <enum>, <int> TESTs:AUTO:VARiable:TCH:CHANnel2:EXPand? TESTs:AUTO:VARiable:TCH:CHANnel3:EXPand <enum>, <int> TESTs:AUTO:VARiable:TCH:CHANnel3:EXPand? 5-92 N9360A Multi UE Tester GSM Programming Manual...
Page 151
These six query commands return the radio system of the measurement test with strings, and channel number of Traffic Channel with integer. The range of the value is the same as that of the command parameter. Talk Test Result TESTs:AUTO:MEASure:TALK PASS|FAIL N9360A Multi UE Tester GSM Programming Manual 5-93...
Page 152
12 bits are as follows: bit 0 (1): Location Update bit 1 (2): 1st Call bit 2 (4): Talk bit 3 (8): 1st Release bit 4 (16): 2nd Call 5-94 N9360A Multi UE Tester GSM Programming Manual...
Page 153
The maximum digit of <string> is 15 and the range of a digit is from 0 to 9. The value is set a value without double quotation. Preset value is 001012345678901. This query command returns IMSI. N9360A Multi UE Tester GSM Programming Manual 5-95...
3 (8): Phase Error bit 4 (16): Frequency Error bit 5 (32): Sensitivity bit 6 (64): RX Quality bit 7 (128): RX Level bit 8 (256): NA bit 9 (512): Test aborted 5-96 N9360A Multi UE Tester GSM Programming Manual...
Page 155
Each bit is set to 0 if the test passed or skipped, or each bit is set to 1 if the test failed. If there are no test results, all bits are set to 1, the value 2047 is returned. N9360A Multi UE Tester GSM Programming Manual 5-97...
Page 156
If there are no test results, all bits are set to 1, the value 1023 is returned. • <int 3> contains the system currently being executed. The return value is 1 (W-CDMA), 0 (GSM) or 2 (CDMA2000). 5-98 N9360A Multi UE Tester GSM Programming Manual...
<real 5> (up to 5 letters) are the High, Medium, and Low ranges measured data ranging from -9.9 to 9.9 in dBm. If any measurement result is out of range or the TX Power is not measured from -9.9 in dBm. N9360A Multi UE Tester GSM Programming Manual 5-99...
• <real 3> (4 letters) is the measured data ranging from -9.9 to 9.9 in bits. If measurement result is out of range or the Burst Timing is not measured, the value -9.9 is returned. 5-100 N9360A Multi UE Tester GSM Programming Manual...
Page 159
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail). Power Ramp Graph Zoom TESTs:AUTO:RESults:RAMP1:ZOOM ON|OFF|1|0 TESTs:AUTO:RESults:RAMP1:ZOOM? TESTs:AUTO:RESults:RAMP2:ZOOM ON|OFF|1|0 TESTs:AUTO:RESults:RAMP2:ZOOM? TESTs:AUTO:RESults:RAMP3:ZOOM ON|OFF|1|0 TESTs:AUTO:RESults:RAMP3:ZOOM? TESTs:AUTO:RESults:RAMP4:ZOOM ON|OFF|1|0 TESTs:AUTO:RESults:RAMP4:ZOOM? TESTs:AUTO:RESults:RAMP5:ZOOM ON|OFF|1|0 TESTs:AUTO:RESults:RAMP5:ZOOM? TESTs:AUTO:RESults:RAMP6:ZOOM ON|OFF|1|0 TESTs:AUTO:RESults:RAMP6:ZOOM? N9360A Multi UE Tester GSM Programming Manual 5-101...
Page 160
-8.00 to 2.00 (bits) and 145.00 to 155.00 (bits) when the zoom function is set to on. • <real 4> (up to 5 letters) is the measured power level at the marker position. 5-102 N9360A Multi UE Tester GSM Programming Manual...
Page 161
145.00 to 155.00 (bits) when the zoom function is set to on, on the Power Ramp graph for each of the six measurement channels. When the measurement result is out of range, or the Power Ramp is not measured, 0.00 is returned. N9360A Multi UE Tester GSM Programming Manual 5-103...
RMS and peak phase error data ranging from 0.0 to 99.9 in ° (degrees). If any measurement result is out of the measurement range or the phase error is not measured, the value 99.9 is returned. 5-104 N9360A Multi UE Tester GSM Programming Manual...
Page 163
• <real 4> (up to 5 letters) is the measured phase error at the marker position. If any measurement result is out of range or the Phase Error is not measured, the value 99.9 is returned. N9360A Multi UE Tester GSM Programming Manual 5-105...
Page 164
<real> bits ranging from 0.00 to 147.00 bits, on the Phase Error graph for each of the six measurement channels. When the measurement result is out of range, or the Power Ramp is not measured, 0.00 is returned. 5-106 N9360A Multi UE Tester GSM Programming Manual...
Page 165
TESTs:AUTO:RESults:RAMP1:TRACe:STARt? TESTs:AUTO:RESults:RAMP2:TRACe:STARt <real> TESTs:AUTO:RESults:RAMP2:TRACe:STARt? TESTs:AUTO:RESults:RAMP3:TRACe:STARt <real> TESTs:AUTO:RESults:RAMP3:TRACe:STARt? TESTs:AUTO:RESults:RAMP4:TRACe:STARt <real> TESTs:AUTO:RESults:RAMP4:TRACe:STARt? TESTs:AUTO:RESults:RAMP5:TRACe:STARt <real> TESTs:AUTO:RESults:RAMP5:TRACe:STARt? TESTs:AUTO:RESults:RAMP6:TRACe:STARt <real> TESTs:AUTO:RESults:RAMP6:TRACe:STARt? This command sets the start point of trace data in Power Ramp for the query command. N9360A Multi UE Tester GSM Programming Manual 5-107...
Page 166
This command sets the number of data in Power Ramp for the query command. The maximum number is 1325. The set value by this command is a common value to TCH1 to TCH6 Manual Test and TX Analyzer. 5-108 N9360A Multi UE Tester GSM Programming Manual...
Page 167
-99. 99 is returned. When the GPIB - USB converter is used, the maximum number of data is N O T E until 300. N9360A Multi UE Tester GSM Programming Manual 5-109...
Page 168
Power Ramp Mask Upper Points TESTs:AUTO:RESults:RAMP1:MASK:UPPer:POINts? TESTs:AUTO:RESults:RAMP2:MASK:UPPer:POINts? TESTs:AUTO:RESults:RAMP3:MASK:UPPer:POINts? TESTs:AUTO:RESults:RAMP4:MASK:UPPer:POINts? TESTs:AUTO:RESults:RAMP5:MASK:UPPer:POINts? TESTs:AUTO:RESults:RAMP6:MASK:UPPer:POINts? This query command returns the number of lower limit sections in the Power Ramp template. • <int> is 13. It is a fixed value. 5-110 N9360A Multi UE Tester GSM Programming Manual...
Page 171
TESTs:AUTO:RESults:FREQuency6:EXPand? These query commands return the Frequency Error measurement result values <int 1>, <int 2> and <real 3> for each of the six measurement channels. Each value is separated by a comma. N9360A Multi UE Tester GSM Programming Manual 5-113...
0 (1): Pass or Fail result for Sensitivity BER II (bit error rate) bit 1 (2): Pass or Fail result for Sensitivity FER (frame erasure rate) bit 2 (4): Pass or Fail result for Sensitivity BER IB (bit error rate) 5-114 N9360A Multi UE Tester GSM Programming Manual...
RX Quality is not measured, the value 7 is returned. Table 5-25 RX Quality Factor: RX Quality: [%] <0.2 0.2 to 0.4 6.4 to 12.8 >12.8 N9360A Multi UE Tester GSM Programming Manual 5-115...
RX Level is not measured, the value 63 is returned. Table 5-26 RX Level Factor: RX Level: [dBm] <–110 –110 to –109 –49 to –48 >–48 5-116 N9360A Multi UE Tester GSM Programming Manual...
(<int>) of GSM mobile phone under test. At preset, this is set to 0. If the mode is set to GPRS/EGPRS, the commands for DIAL, PCLass N O T E and GVERsion are invalid. N9360A Multi UE Tester GSM Programming Manual 5-117...
Table 5-27 BCCH Channel Allowable Range and Preset Value RFORmat Allowable Range Preset Value GSM850 128 to 251 GSM900 955 to 1023, 0 to 124 DCS1800 512 to 885 PCS1900 512 to 810 5-118 N9360A Multi UE Tester GSM Programming Manual...
5-118 change synchronously. This query command returns the set frequency of the Broadcast Control Channel with real. The range of the value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-119...
5-120 change synchronously. This query command returns the set frequency of the Traffic Channel with real. The range of the value is same as that of the command parameter. TESTs:MANual:TCH:FREQuency:EXPand <enum>,<int> TESTs:MANual:TCH:FREQuency:EXPand? N9360A Multi UE Tester GSM Programming Manual 5-121...
This command sets a value of Power Control Level for each radio system set by the Radio System command described on page 5-118. The allowable range and preset values are as follows: 5-122 N9360A Multi UE Tester GSM Programming Manual...
[Stand-by] screen for the GPRS/EGPRS mode, in conjunction with the Slot Order Measured setting. The combinations of the slot configuration and the slot order measured are as follows: N9360A Multi UE Tester GSM Programming Manual 5-123...
Page 183
This query command returns the set of the Phase Error and Frequency Error test with integer value of 1 or 0. The meaning of the return value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-125...
Page 184
This query command returns the set averaging. RF Signal Output Mode TESTs:MANual:RFOUtput ON|OFF|1|0 TESTs:MANual:RFOUtput? This command sets the RF Output mode. The parameter is ON (1) or OFF (0). At preset, this is set to 1. 5-126 N9360A Multi UE Tester GSM Programming Manual...
Page 185
This is not initialized by PRESET execution with the Starting Condition softkey. This query command returns the set Caller ID with string. This command is valid only for the Manual Test. N O T E N9360A Multi UE Tester GSM Programming Manual 5-127...
Page 186
The maximum digit of <string> is 15 and the range of a digit is from 0 to 9. The value is set a value without double quotation. Preset value is 001012345678901. This query command returns IMSI. 5-128 N9360A Multi UE Tester GSM Programming Manual...
Tester. BS Call TESTs:MANual:BSCall This command executes a call setup to the mobile phone from the Tester. BS Release TESTs:MANual:BSRelease This command releases the call from the Tester. N9360A Multi UE Tester GSM Programming Manual 5-129...
Page 188
GSM mode. The return value contains the status in execution of 10 bits as follows. bit 0 (1): MS Call/BS Call bit 1 (2): Talk/RF Test bit 2 (4): MS Release/BS Release bit 3 (8): Time Out Error 5-130 N9360A Multi UE Tester GSM Programming Manual...
Page 189
The step in execution is set to 1, and the others are set to 0. The value in the parentheses is decimal value for each bit. Refer to Setting and Querying the Registers page 4-18. N9360A Multi UE Tester GSM Programming Manual 5-131...
Page 190
<int 2> contains the system currently being executed. The return value is 1 (W-CDMA), 0 (GSM) or 2 (CDMA2000). When GPRS/EGPRS mode is set, refer to Signaling State (GPRS/EGPRS N O T E mode) 5-132 N9360A Multi UE Tester GSM Programming Manual...
Page 191
GPRS/EGPRS mode. The following 7-bit values are returned. bit 0 (1): Idle or End bit 1 (2): Attached bit 2 (4): Connected bit 3 (8): Timeout Error bit 4 (16): NA bit 5 (32): NA bit 6 (64): Busy N9360A Multi UE Tester GSM Programming Manual 5-133...
Page 192
• <int 2> contains the system currently being executed. The return value is 1 (W-CDMA), 0 (GSM) or 2 (CDMA2000). If the mode is set to GSM, this command is invalid. N O T E 5-134 N9360A Multi UE Tester GSM Programming Manual...
This command sets GPRS Coding Scheme. The allowable range is 1 to 4. At preset, this is set to 1. If the mode is set to GSM or EGPRS, this command is invalid. N O T E N9360A Multi UE Tester GSM Programming Manual 5-135...
Page 194
If there are no test results, all bits are set to 1 and the value 511 is returned. When the GPRS/EGPRS mode is currently set, the number of bits used N O T E and meaning each bit are not the same as the other modes. 5-136 N9360A Multi UE Tester GSM Programming Manual...
Page 195
• <int 2> contains the system currently being executed. The return value is 1 (W-CDMA), 0 (GSM) or 2 (CDMA2000). If the mode is set to GSM/EGPRS, this command is invalid. N O T E N9360A Multi UE Tester GSM Programming Manual 5-137...
Page 196
If there are no test results, all bits are set to 1 and the value 511 is returned. • <int 2> contains the system currently being executed. The return value is 1 (W-CDMA), 0 (GSM) or 2 (CDMA2000). 5-138 N9360A Multi UE Tester GSM Programming Manual...
This query command returns a value of RX Quality. • <int 1> (1 digit) is 0 if measurement result is within the measurement range, or 1 if measurement result is out of range or the RX Quality is not measured. N9360A Multi UE Tester GSM Programming Manual 5-139...
Page 198
This query command returns the value of RF Power. From <int1> to <int8> in sequence, the value of GMSK/GSM850, GSMK/GSM900, GSMK/DCS1800, GSMK/PCS1900, 8-PSK/GSM850, 8-PSK/GSM900, 8-PSK/DCS1800 and 8-PSK/PCS1900 are assigned. Each value is separated by a comma. 5-140 N9360A Multi UE Tester GSM Programming Manual...
1 if measurement result is out of range or the Power Ramp is not measured. • <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail). N9360A Multi UE Tester GSM Programming Manual 5-141...
Page 200
• <int 2> (1 digit) contains test results by sum of value of 2 bits as follows. bit 0 (1): Pass or Fail result for RMS Phase Error bit 1 (2): Pass or Fail result for Peak Phase Error 5-142 N9360A Multi UE Tester GSM Programming Manual...
Page 201
1 if measurement result is out of range or the Frequency Error is not measured. • <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail). N9360A Multi UE Tester GSM Programming Manual 5-143...
Page 202
1 if measurement result is out of range or the Origin Offset Spr. is not measured. • <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail). 5-144 N9360A Multi UE Tester GSM Programming Manual...
Page 203
<real> bits ranging from 0.00 to 423.00 in bits. This command is valid when the Modulation and Coding Scheme is set N O T E from MCS5 to MCS9 in EGPRS mode. N9360A Multi UE Tester GSM Programming Manual 5-145...
-9.25 to 156.25 when the zoom function is set to Off, or from -8.00 to 2.00 and 145.00 to 155.00 when the zoom function is set to On. 5-146 N9360A Multi UE Tester GSM Programming Manual...
Page 205
<real> in bits ranging from -27.75 to 468.75 when the zoom function is set to Off, or from -24.00 to 6.00 and 435.00 to 465.00 when the zoom function is set to On. N9360A Multi UE Tester GSM Programming Manual 5-147...
Page 206
The step is 0.375 Bits step and the number of data is 1325 in 8PSK. The set value by this command is a common value to TCH1 to TCH6 Manual Test and TX Analyzer. 5-148 N9360A Multi UE Tester GSM Programming Manual...
Page 207
1 if measurement result is out of range or the Access Probe Power is not measured. • <real2> is the start point of data. • <real3> is the number of step. N9360A Multi UE Tester GSM Programming Manual 5-149...
Page 208
<real21>, <real23>, <real25> show the point of section end (Bits). Refer the Table 5-37. • <real2>, <real4>, <real6>, <real8>, <real10>, <real12>, <real14>, <real16>, <real18>, <real20>, <real22>, <real24>, <real26> show the limit value (dB). 5-150 N9360A Multi UE Tester GSM Programming Manual...
<real21>, <real23>, <real25> show the point of section end (Bits). Refer the Table 5-38. • <real2>, <real4>, <real6>, <real8>, <real10>, <real12>, <real14>, <real16>, <real18>, <real20>, <real22>, <real24>, <real26> show the limit value (dB). N9360A Multi UE Tester GSM Programming Manual 5-151...
Phase Error Marker Position Control TESTs:MANual:RESults:PHASe:MARKer:POINt UP|DOWN TESTs:MANual:RESults:PHASe:MARKer:POINt <real> TESTs:MANual:RESults:PHASe:MARKer:POINt? This command moves the marker position Up or Down in steps, or by <real> bits ranging from 0.00 to 147.00 in bits. N9360A Multi UE Tester GSM Programming Manual 5-153...
1 if measurement result is out of range or the RX Level is not measured. • <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail). 5-154 N9360A Multi UE Tester GSM Programming Manual...
Page 213
A. Each value is separated by a comma. • <int 1> (1 digit) is 0 if measurement results are within the measurement range, or 1 if any measurement result is out of range or the Sensitivity is not measured. N9360A Multi UE Tester GSM Programming Manual 5-155...
Page 214
Sensitivity is not measured, the value 99.99 is returned. If the mode is set to GSM, refer to Sensitivity BER and FER Measurement N O T E (GSM mode, Testloop Mode A) page 5-155. 5-156 N9360A Multi UE Tester GSM Programming Manual...
Page 215
The above commands are valid only for corresponding mode setting. N O T E Sensitivity Test Frames GSM Mode, Test Loop A TESTs:MANual:SENSitivity:FRAMe <int> TESTs:MANual:SENSitivity:FRAMe? GSM Mode, Test Loop C TESTs:MANual:SENSitivity:FRAMe:BERFast <int> TESTs:MANual:SENSitivity:FRAMe:BERFast? N9360A Multi UE Tester GSM Programming Manual 5-157...
Page 216
Coding Scheme is set to MCS3, MCS4, MCS7, MCS8, and MCS9. This command is valid when the GSM mode is set to EGPRS mode. N O T E 5-158 N9360A Multi UE Tester GSM Programming Manual...
ORFS Modulation TESTs:MANual:ORFS:MOD:STATe ON|OFF|0|1 TESTs:MANual:ORFS:MOD:STATe? This command sets whether to execute each measurement item of the ORFS Modulation. The parameter is ON (1) or OFF (0). At preset, this is set to 1. N9360A Multi UE Tester GSM Programming Manual 5-159...
Page 218
• <real 3> is the Lower value and <real 4> is the Upper value of the measurement results. If the measurement result is out of range or the ORFS Modulation is not measured, the value 99.99 is returned. 5-160 N9360A Multi UE Tester GSM Programming Manual...
Page 219
ORFS Switching is not measured, the value 99.99 is returned. Ref. Power TESTs:MANual:RESults:ORFS:Power? This query command returns the Ref. Power measurement result value, <int>. The parameter is ranging from -99.99 to 99.99. N9360A Multi UE Tester GSM Programming Manual 5-161...
For details, consult the item SMS Data Coding Scheme in ETSI TS 123 038 V5.0.0. This query command returns the set MT sent binary message. The return values are same as the command parameter. Each value is separated by a comma. 5-164 N9360A Multi UE Tester GSM Programming Manual...
Page 223
• <string 4> indicates the received message. This command is valid when the mode is set to GSM mode. N O T E SMS-CB TESTs:MANual:SMSCb This command starts SMS-CB. SMS-MT TESTs:MANual:SMSMt This command starts SMS-MT. N9360A Multi UE Tester GSM Programming Manual 5-165...
5-167 change synchronously. This query command returns the set channel number to be tested with integer. The range of the value is same as that of the command parameter. 5-166 N9360A Multi UE Tester GSM Programming Manual...
5-166 change synchronously. This query command returns the set frequency to be tested with real. The range of the value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-167...
This command selects a signaling type from the mobile phone for analysis. The parameter is BURST or CW. At preset, this is set to BURST. This query command returns the selected signal type with strings of BURST or CW. 5-168 N9360A Multi UE Tester GSM Programming Manual...
Page 227
This query command returns the set of the Phase Error, Frequency Error, EVM and Origin Offset Spr. test with integer value of 1 or 0. The meaning of the return value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-169...
Page 228
GMSK or PSK (8-PSK). At preset, this is set to GMSK. Frequency Offset TXANalyzer:OFFSet <int> TXANalyzer:OFFSet? This command sets the frequency offset. The allowable range is from -100.0 to 100.0 kHz in 0.1 steps. At preset, this is set to 0.0 (kHz). 5-170 N9360A Multi UE Tester GSM Programming Manual...
Page 229
TXANalyzer:SYSTem? This command causes switching to the specified system (GSM, W-CDMA and CDMA2000). It is enabled in the standby status. Query of this command obtains the specified system in the character string. N9360A Multi UE Tester GSM Programming Manual 5-171...
• <real 3> (up to 5 letters) is the measured data ranging from -99.9 to 99.9 in dBm. If measurement result is out of range or the Peak TX Power is not measured, the value -99.9 is returned. 5-172 N9360A Multi UE Tester GSM Programming Manual...
Page 231
1 if measurement result is out of range or the Power Ramp is not measured. • <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail). N9360A Multi UE Tester GSM Programming Manual 5-173...
Page 232
DOWN in steps, or by <real> ranging from -27.75 to 468.75 in bits when the zoom function is set to Off, or from -24.00 to 6.00 and 435.00 to 465.00 when the zoom function is set to On. 5-174 N9360A Multi UE Tester GSM Programming Manual...
Page 233
The step is 0.375 Bits step and the number of data is 1325 in 8PSK. The set value by this command is a common value to TCH1 to TCH6 Manual Test and TX Analyzer. N9360A Multi UE Tester GSM Programming Manual 5-175...
Page 234
1 if measurement result is out of range or the Access Probe Power is not measured. • <real2> is the start point of data. • <real3> is the number of step. 5-176 N9360A Multi UE Tester GSM Programming Manual...
Page 235
<real21>, <real23>, <real25> show the point of section end (Bits). Refer the Table 5-45. • <real2>, <real4>, <real6>, <real8>, <real10>, <real12>, <real14>, <real16>, <real18>, <real20>, <real22>, <real24>, <real26> show the limit value (dB). N9360A Multi UE Tester GSM Programming Manual 5-177...
<real21>, <real23>, <real25> show the point of section end (Bits). Refer the Table 5-46. • <real2>, <real4>, <real6>, <real8>, <real10>, <real12>, <real14>, <real16>, <real18>, <real20>, <real22>, <real24>, <real26> show the limit value (dB). 5-178 N9360A Multi UE Tester GSM Programming Manual...
99.9 in ° (degrees). If any measurement result is out of range or the Phase Error is not measured, the value 99.9 is returned. This command is valid when Demodulation is set to GMSK. N O T E 5-180 N9360A Multi UE Tester GSM Programming Manual...
Page 239
• <real 3> (up to 7 letters) is the measured Frequency Error data ranging from -99999.9 to 99999.9 (Hz) in 0.1 steps. If measurement result is out of range or the Frequency Error is not measured, the value 99999.9 is returned. N9360A Multi UE Tester GSM Programming Manual 5-181...
Page 240
<real> ranging from 0.00 to 147.00 in bits, in the Phase Error graph for each of the six measurements. This command is valid when Demodulation is set to GMSK. N O T E 5-182 N9360A Multi UE Tester GSM Programming Manual...
Page 241
• <real 4> (up to 6 letters) is the measured EVM Marker data ranging from 0.00 to 99.99 (%). This command is valid when the Demodulation is set to 8-PSK. N O T E Installation of the Option G03 is required. N9360A Multi UE Tester GSM Programming Manual 5-183...
Page 242
Offset. If the measurement result is out of range or the Origin Offset is not measured, the value 99.99 is returned. This command is valid when Demodulation is set to 8-PSK. N O T E Installation of the Option G03 is required. 5-184 N9360A Multi UE Tester GSM Programming Manual...
1 to 200. At preset, this is set to 1. ORFS Modulation Measurement TXANalyzer:RESults:ORFS:MOD? This query command returns the ORFS Modulation measurement result values <int 1>, <int 2>, <real 1> and <real 2>. Each value is separated by a comma. N9360A Multi UE Tester GSM Programming Manual 5-185...
Page 244
If the measurement result is out of range or the ORFS Switching is not measured, the value 99.99 is returned. Ref. Power TXANalyzer:RESults:ORFS:Power? This query command returns the Ref. Power measurement result value, <real>. The parameter is ranging from -99.99 to 99.99. 5-186 N9360A Multi UE Tester GSM Programming Manual...
If the 0 to 400 kHz span is selected by the Display Span command described above, this query command returns measurement result values <int 1>, <int 2>, <real 3>, <real 4>, and <real 5>. Each value is separated by comma. N9360A Multi UE Tester GSM Programming Manual 5-187...
This command moves the marker UP or DOWN in steps, or by a numeric value <real>. The allowable range is from 0 to 400000 (Hz) for the 0 to 400 kHz span, or from -100000 to 100000 (Hz) for the ±100 kHz span. N9360A Multi UE Tester GSM Programming Manual 5-189...
Table 5-49 RFCH Allowable Range and Preset Value RFORmat Allowable Range Preset Value GSM850 128 to 251 GSM900 0 to 124, 955 to 1023 DCS1800 512 to 885 PCS1900 512 to 810 5-190 N9360A Multi UE Tester GSM Programming Manual...
-110.0 to -20.0 (dBm) in 0.1 steps. At preset, this is set to -50.0 (dBm). This query command returns the set output amplitude with real. The range of the value is same as that of the command parameter. N9360A Multi UE Tester GSM Programming Manual 5-191...
Page 250
GMSK modulation with PN9 data. • GMSK:PN15 GMSK modulation with PN15 data. • GMSK:All0 GMSK modulation with all-zero data. • GMSK:All1 GMSK modulation with all-one data. • AM Applies AM modulation to the carrier. 5-192 N9360A Multi UE Tester GSM Programming Manual...
Page 251
ON (1) or OFF (0). At preset, this is set to 0. Change System RFGenerator:SYSTem GSM|WCDMA|CDMA2000 RFGenerator:SYSTem? This command causes switching to the specified system (GSM, W-CDMA and CDMA2000). Query of this command obtains the specified system in the character string. N9360A Multi UE Tester GSM Programming Manual 5-193...
Programming Command Reference HCOPy Subsystem The HCOPy commands are used to control the printing function. HCOPy Subsystem Command Reference Print Screen Image HCOPy:SDUMp This command executes to print a screen image. 5-194 N9360A Multi UE Tester GSM Programming Manual...
These commands store four settings of Amplitude or Channel into Memory 1, 2, 3 and 4. The stored values are displayed on those softkeys. These query commands return the stored values with real and integer. N9360A Multi UE Tester GSM Programming Manual 5-195...
Page 254
Table 4-6 for the listings of the error messages. Menu Screen SYSTem:RBT This command returns to the [Top Menu] Screen. It is effective when the response of the Display? query command is INIT. 5-196 N9360A Multi UE Tester GSM Programming Manual...
This command selects the trigger mode to either a single or continuous (repetitive) measurement. The parameter is SINGle or CONTinuous. At preset, this is set to SING. This query command returns the selected trigger mode with string. N9360A Multi UE Tester GSM Programming Manual 5-197...
Page 256
Programming Command Reference THIS PAGE IS INTENTIONALLY LEFT BLANK. 5-198 N9360A Multi UE Tester GSM Programming Manual...
Signal Generator Screen 6-41 Print Screen Function 6-42 System Control Function 6-42 Trigger Function 6-43 This chapter contains summary tables for correlating the screens, softkeys, test parameters and test items with their corresponding syntax for control the Tester. Agilent Technologies...
Table 6-2 Top Menu Command Summary Item Command System Error SYST:ERR? Lock System Panel SYST:KLOC ON|OFF|1|0 SYST:KLOC? Current Screen DISP? Top Menu Screen DISP:INIT System Configuration DISP:CONF Application Type DISP:APPL GSM Application APPL:GSM N9360A Multi UE Tester GSM Programming Manual...
Page 259
Time Entry CONF:TIME <int HH>,<int MM> CONF:TIME? Autoboot CONF:AUTOB none|GSM|WCDMA << CDMA2000,<int> CONF:AUTOB? RF Revision CONF:REV:RF? Update Type UPDA:TYPE USB|HDD|SERVER UPDA:TYPE? Update Result UPDA:RES? Update History UPDA:HIST? Update History Position UPDA:HIST:POS <int> UPDA:HIST:POS? N9360A Multi UE Tester GSM Programming Manual...
Page 260
UPDA:FIRM:REV:FUNC? G00 Firmware Revision UPDA:FIRM:REV:G00? W00 Firmware Revision UPDA:FIRM:REV:W00? Update Flash UPDA:FLAS:TRIG MC1X|1XEVDO Update MC-1x Flash List UPDA:FLAS:LIST:MC1X? Update 1xEV-DO Flash List UPDA:FLAS:LIST:1XEVDO? MC-1x Flash ROM Revision UPDA:FLAS:REV:MC1X? 1xEV-DO Flash ROM Revision UPDA:FLAS:REV:1XEVDO? N9360A Multi UE Tester GSM Programming Manual...
Signal Generator Screen RF Signal Generator DISP:RFG Initial Softkey Screen The following command is used to set [Initial Softkey] screen. Table 6-4 INITialsoftkey Subsystem Command Summary Item Command Current System INIT:CUR WCDMA|GSM|CDMA2000 INIT:CUR? N9360A Multi UE Tester GSM Programming Manual...
Following commands are used to set the [Configuration: NetworkSetting] screen-related control and parameters. Table 6-11 Network Command Summary Item Command Apply Address CONF:NET:APPLY:ADDR IP Address CONF:NET:IP <string IPADDRESS>,<int> CONF:NET:IP? Default Gateway CONF:NET:DEF:GATE << <enum>,<string DEFAULTGATEWAY> CONF:NET:DEF:GATE? 6-18 N9360A Multi UE Tester GSM Programming Manual...
Table 6-16 MSINformation Command Summary Item Command IMSI Information TEST:MAN:RES:MSIN:IMSI? IMEI Information TEST:MAN:RES:MSIN:IMEI? Dialed Number Information TEST:MAN:RES:MSIN:DIAL? Power Class Information TEST:MAN:RES:MSIN:PCL? GSM Version TEST:MAN:RES:MSIN:GVER? RX Quality TEST:MAN:RES:MSIN:QUAL? RX Level TEST:MAN:RES:MSIN:LEV? 6-30 N9360A Multi UE Tester GSM Programming Manual...
Quality/RX Level measurements and to get measurement results and Pass/Fail test results. Table 6-19 Manual Test SENSitivity/RX Command Summary Item Command Power Control Level TEST:MAN:SENS:PLEV <int> TEST:MAN:SENS:PLEV? BER BS Level TEST:MAN:SENS:LEV <real> TEST:MAN:SENS:LEV? 6-32 N9360A Multi UE Tester GSM Programming Manual...
The following commands are used to set the controls and parameters associated with the screens for ORFS measurements and to get measurement results and Pass/Fail test results. Table 6-20 Manual Test ORFS Command Summary Item Command ORFS Modulation TEST:MAN:ORFS:MOD:STAT ON|OFF|0|1 TEST:MAN:ORFS:MOD:STAT? N9360A Multi UE Tester GSM Programming Manual 6-33...
Trigger Function The following commands are used to control the trigger function of the Tester. Table 6-31 TRIGger Subsystem Command Summary Item Command Trigger Immediately TRIG:IMM Trigger Mode TRIG:MODE SING|CONT TRIG:MODE? Abort TRIG:ABOR N9360A Multi UE Tester GSM Programming Manual 6-43...
Page 300
Programming Command Summary THIS PAGE IS INTENTIONALLY LEFT BLANK. 6-44 N9360A Multi UE Tester GSM Programming Manual...
Page 301
This chapter contains an example program contained to be used for testing a GSM850, GSM900, DCS1800 or PCS1900 mobile phone with the Tester. Following program use Microsoft Windows and Microsoft Visual Basic. Refer to the instruction manual of Visual Basic for further details about Visual Basic. Agilent Technologies...
The followings section describes the program structure. Components of Screen. (Refer to "Components of Window 7-3"). Functions (status display, sent and received data) (Refer to "Functions 7-4"). Test Events (Refer to "Test Event 7-5"). N9360A Multi UE Tester GSM Programming Manual...
Table 7-1. Test buttonsStarts each test by pressing a button. Status fieldDisplays the status and results of the test. This program runs with the configuration shown in Table 7-1. N9360A Multi UE Tester GSM Programming Manual...
7-2. Refer to source code file, sample.bas in the CD-R for detail operation. Table 7-2 Status Display Functions Subroutine Name Capability AddStatus string Displays the string in the status field. ClrStatus Clears the status field. N9360A Multi UE Tester GSM Programming Manual...
Initialize the interface specified on the Interface field. Execute the Test Function according to the pressed test button. (Refer to Automatic Test Function TX Analyzer Function) Close the interface specified on the Interface field. N9360A Multi UE Tester GSM Programming Manual...
Starts the Automatic Test. Displays message to an operator: Turn on the mobile phone. Waits until the location update is completed. Displays message to an operator: Please MS Call. Waits until signaling test is completed. N9360A Multi UE Tester GSM Programming Manual...
Page 309
Queries the measurement result of Frequency Error. Displays the measurement value and Pass or Fail result of Frequency Error on the status field. Displays the [Automatic Test : Stand-by] screen. Displays Complete message on the status field. N9360A Multi UE Tester GSM Programming Manual...
: OUTPUT "TEST:MAN:RFOR DCS1800" : WAIT "TEST:MAN:SIGN:STAT?", 16 : AddStatus "Turn on the mobile phone." : WAIT "TEST:MAN:SIGN:STAT?", 32 : AddStatus "Wait until the [Location Update] is passed." : WAIT "TEST:MAN:SIGN:STAT?", 16 : OUTPUT "TEST:MAN:BSC" 7-10 N9360A Multi UE Tester GSM Programming Manual...
Page 311
"Hz " + IIf(value(1) And 1, "FAIL", "PASS") :' BS Release : OUTPUT "TEST:MAN:BSR" : AddStatus "Complete" : End Sub Table 7-5 Program Comments Line Description Declares the variable to store test results. Erases the status field. N9360A Multi UE Tester GSM Programming Manual 7-11...
Page 312
Queries the measurement result of Frequency Error. Displays the measurement value and Pass or Fail result of Frequency Error on the status field. Executes the BS Release. Displays Complete message on the status field. 7-12 N9360A Multi UE Tester GSM Programming Manual...
: OUTPUT "CONF:LOSS:RFOU 1.0,1.0,1.0,1.0" : OUTPUT "CONF:COND:MODE GPRS" :'Measure Setup : OUTPUT "TEST:MAN:RFOR DCS1800" : WAIT "TEST:MAN:SIGN:STAT?", 1 : AddStatus "Turn on the mobile phone." : WAIT "TEST:MAN:SIGN:STAT?", 2 'wait for Attached : AddStatus "Attached" N9360A Multi UE Tester GSM Programming Manual 7-13...
Page 314
: value = Split(ENTER("TEST:MAN:RES:FREQ?"), ",") : AddStatus "Frequency Error : " + value(2) + "Hz " + IIf(value(1) And 1, "FAIL", "PASS") :'BS Release : OUTPUT "TEST:MAN:BSR" : AddStatus "Complete" : End Sub 7-14 N9360A Multi UE Tester GSM Programming Manual...
Page 315
Queries the measurement result of Frequency Error. Displays the measurement value and Pass or Fail result of Frequency Error on the status field. Executes the BS Release. Displays Complete message on the status field. N9360A Multi UE Tester GSM Programming Manual 7-15...
: WAIT "*STB?", 0 : value = Split(ENTER("TXAN:RES:TXP?"), ",") : AddStatus "Peak TX Power :" + value(2) + "dBm " + IIf(value(1) And 1, "FAIL", "PASS") :' Phase Error & Freq Error 7-16 N9360A Multi UE Tester GSM Programming Manual...
Page 317
Queries the measurement result of Peak TX Power. Displays the measurement value and Pass or Fail result of Peak TX Power on the status field. Displays the [Phase Error/Frequency Error] screen on the Tester. N9360A Multi UE Tester GSM Programming Manual 7-17...
Page 318
Displays the measurement value and Pass or Fail result of Frequency Error on the status field. Displays the [TX Analyzer : Stand-by] Screen on the Tester. Displays "Complete" message on the status field. 7-18 N9360A Multi UE Tester GSM Programming Manual...
Page 319
Appendix A Syntax Diagrams Graphical Conversions Syntax Diagrams In this Appendix, the syntax diagram for each subsystem commands is shown. These diagrams use a graphical format to represent the hierarchical structure of the system. Agilent Technologies...
Page 320
: Indicates the series of command parts are omitted in the chart. Query commands have different return values. Consult with the other section in this guide or the User's Guide for detailed information. N9360A Multi UE Tester GSM Programming Manual...
HI PHASe real HI PEAK? real HI PEAK FREQuency? FREQuency real HI real LO FREQuency EXPand? FREQuency EXPand real2 real 1 real HI real HI Figure A-9 Configure Subsystem (Continued) 3 A-10 N9360A Multi UE Tester GSM Programming Manual...
MARKer POINt? POINt enum real PHASe5? PHASe5 MARKer? PHASe5 MARKer POINt? POINt enum real PHASe6? PHASe6 MARKer? PHASe6 MARKer POINt? POINt enum real Figure A-22 TESTs Subsystem for Automatic Test (Continued) 6 A-22 N9360A Multi UE Tester GSM Programming Manual...
Page 342
FREQuency EXP? enum RFEQuency long PLEVel? PLEVel AMPLitude? AMPLitude long TADVance? TADVance TXPower STATe? STATe bool PHASe STATe? STATe bool SENSitivity STATe? STATe bool Figure A-24 TESTs Subsystem for Manual Test A-24 N9360A Multi UE Tester GSM Programming Manual...