Advertisement

5
Programming Command Reference
FER Confidence
CONFigure:CONDition:FER:CONFidence 95%|OFF
CONFigure:CONDition:FER:CONFidence?
This command is valid when CDMA mode is set to MC1X. This
sets the FER Confidence. The parameter is 95% or OFF. At preset,
this is set to 95%.
This query command returns the setting of FER Confidence with
the value of 95% or OFF.
Nominal Power
CONFigure:CONDition:PNOMinal <int>
CONFigure:CONDition:PNOMinal?
This command is valid when CDMA mode is set to MC1X. This
sets the Nominal Power in each band set by the
Band
command
36. The allowable range is from -8 to 7 in 1 steps. At
on
page
preset, this is set to 0.
This query command returns the set Nominal Power with integer.
The range of the value is same as that of the command
parameter.
Initial Power
CONFigure:CONDition:PINitial <int>
CONFigure:CONDition:PINitial?
This command is valid when CDMA mode is set to MC1X. This
sets the Initial Power in each band set by the
Band
command. The
allowable range is from -16 to 15 in 1 steps. At preset, this is
set to 0.
This query command returns the set Initial Power with integer.
The range of the value is same as that of the command
parameter.
Power Step
CONFigure:CONDition:PSTep <int>
CONFigure:CONDition:PSTep?
N9360A Multi UE Tester CDMA2000 Programming Manual
5-59