5
Programming Command Reference
5-86
bit 5 (32) :Talk (From BS Call (Talk))
bit 6 (64) :BS Release/Handoff (From BS Call (Talk) or Talk)
bit 7 (128) :BS Call (RF Test)
bit 8 (256) :RF Test (From BS Call (RF Test))
bit 9 (512) :Softer Handoff (From BS Call (RF Test) or
RF Test)
bit 10 (1024) :BS Release/Handoff (From BS Call (RF Test),
RF Test, or Softer Handoff)
bit 11 (2048) :Measurement end with test result
bit 12 (4096) :Measurement end without test result
(Aborted or Time out error occurred)
The executed step is set to 1, and the others are set to 0.
The value in the parentheses is decimal value for each bit. Refer
to
Setting and Querying the
• <int 2> contains the system type currently being executed.
The return value is 2 (cdma2000), 1 (W-CDMA), or 0 (GSM).
When CDMA mode is EVDO:
• <int 1> contains test contents currently being executed by
sum of the value of 9 bits as follows:
bit 0 (1) :UATI Assign
bit 1 (2) :Session Opened
bit 2 (4) :BS Call
bit 3 (8) :RF Test
bit 4 (16) :Softer Handoff
bit 5 (32) :Connection Close
bit 6 (64) :Session Close
bit 7 (128) :Measurement end with test result
bit 8 (256) :Measurement end without test result
(Aborted or Time out error occurred)
The executed step is set to 1, and the others are set to 0.
The value in the parentheses is decimal value for each bit. Refer
to
Setting and Querying the
N9360A Multi UE Tester CDMA2000 Programming Manual
Registers.
Registers.