Agilent Technologies N9360A Programming Manual page 134

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

5
Programming Command Reference
5-84
Talk Test Result
TESTs:AUTO:MEASure:TALK PASS|FAIL
This command is valid when CDMA mode is set to MC1X. This
verifies whether the test result of the Talk step passes or fails.
The parameter is PASS or FAIL.
Signaling State
TESTs:AUTO:MEASure:SIGNaling:STATe?
This command requires the installation of the Option C02.
The return value of this query command differs depending on
the CDMA mode (MC1X or EVDO).
When CDMA mode is MC1X:
This query command returns the test step currently executed in
a test cycle. The return value contains the currently executed
status of 13 bits as follows:
bit 0 (1) :Location Update
bit 1 (2) :MS Call (Talk)
bit 2 (4) :Talk (From MS Call (Talk))
bit 3 (8) :MS Release (From MS Call (Talk) or Talk)
bit 4 (16) :BS Call (Talk)
bit 5 (32) :Talk (From BS Call (Talk))
bit 6 (64) :BS Release/Handoff (From BS Call (Talk) or Talk)
bit 7 (128) :BS Call (RF Test)
bit 8 (256) :RF Test (From BS Call (RF Test))
bit 9 (512) :Softer Handoff (From BS Call (RF Test) or
RF Test)
bit 10 (1024) :BS Release/Handoff (From BS Call (RF Test),
RF Test, or Softer Handoff)
bit 11 (2048) :Measurement end with test result
bit 12 (4096) :Measurement end without test result
(Aborted or Time out error occurred)
The executed step is set to 1, and the others are set to 0.