N9360A Multi UE Tester CDMA2000 Programming Manual
This command is valid when CDMA mode is set to MC1X. This
starts connection by manual response during response time
after MS Call initiation.
Call Status Clear
TESTs:MANual:SCLear
This command clears the pass/fail results of the Call Status.
Signaling State
TESTs:MANual:SIGNaling:STATe?
The return value of this query command differs depending on
the CDMA mode (MC1X or EVDO).
When CDMA mode is MC1X:
This query command returns the test step currently executed in
a test cycle. The return value contains the currently executed
status of 10 bits as follows:
bit 0 (1) :MS Call/ BS Call
bit 1 (2) :Talk, RF Test
bit 2 (4) :MS Release/BS Release
bit 3 (8) :Time out error (Currently unused)
bit 4 (16) :End (Stand-by status)
bit 5 (32) :Location Update
bit 6 (64) :Busy
bit 7(128):Softer Handoff
bit 8(256):Hard Handoff/Band Handoff
bit 9(512):System Handoff
Programming Command Reference
5
5-119