Agilent Technologies N9360A Programming Manual page 115

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

N9360A Multi UE Tester CDMA2000 Programming Manual
Sector ID
CONFigure:CONDition:SECTor:ID <<
<int1>,<int2>,<int3>,<int4>,<int5>,<<
<int6>,<int7>,<int8>
CONFigure:CONDition:SECTor:ID?
This command requires the installation of the Option C02.
This command is valid when CDMA mode is set to EVDO. This
sets the Sector ID in each band set by the
36. The allowable range of <int 1> to <int 8> is from
page
0000 to FFFF (hexadecimal number in 1 steps). At preset, this
is set to 0000 (hexadecimal number).
This query command returns the setting of Sector ID with
strings.
Subnet Mask
CONFigure:CONDition:SECTor:MASK <int>
CONFigure:CONDition:SECTor:MASK?
This command requires the installation of the Option C02.
This command is valid when CDMA mode is set to EVDO. This
sets the Subnet Mask in each band set by the
36. The allowable range of <int> is from 00 to FF (hex
page
number in 1 steps). At preset, this is set to 00 (hex number).
This query command returns the setting of Subnet Mask with
strings.
UATI Color Code
CONFigure:CONDition:UATI:COLor <int>
CONFigure:CONDition:UATI:COLor?
This command requires the installation of the Option C02.
This command is valid when CDMA mode is set to EVDO. This
sets the UATI Color Code in each band set by the
The allowable range of <int> is from 00 to FF (hex number in 1
steps). At preset, this is set to 00 (hex number).
This query command returns the setting of UATI Color Code with
strings.
Programming Command Reference
Band
command on
Band
command on
Band
5
command.
5-65