Agilent Technologies N9360A Installation Manual

Multi universal equipment (ue) tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Agilent N9360A
Multi Universal
Equipment (UE) Tester
Installation Guide
Agilent Technologies

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies N9360A

  • Page 1 Agilent N9360A Multi Universal Equipment (UE) Tester Installation Guide Agilent Technologies...
  • Page 2 Agilent Technologies’ standard agreement and written consent from First Edition, April 2006 commercial license terms, and non-DOD Agilent Technologies, Inc. as governed by Departments and Agencies of the U.S. Printed in Malaysia United States and international copyright Government will receive no greater than laws.
  • Page 3: Table Of Contents

    Safety Symbols and Regulatory Markings Declaration of Conformity Electrostatic Discharge (ESD) Precautions End of Life: Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC Overview of the N9360A Multi Universal Equipment (UE) Tester Introduction System Functions Standard Configuration Accessories External Views...
  • Page 4 AC Power Requirements Warm Up Time Ventilation Maintenance, Inspection and Basic Troubleshooting Warnings Daily Inspection Daily Maintenance Basic Troubleshooting Repairs and Services Calibration Agilent N9360A Multi UE Tester Installation Guide...
  • Page 5 List Of Figures Overview of the N9360A Multi Universal Equipment (UE) Tester Figure 3-1. Power Cord Types Figure 3-2. N9360A Front View Figure 3-3. N9360A Front View Figure 3-4. N9360A Rear View Figure 3-5. N9360A Side View Figure 3-6. N9360A Top View Panel Description Figure 4-1.
  • Page 6 Table 2-1. Environment Requirements Table 2-2. Safety Symbols and Regulatory Markings Table 2-3. Suggested Anti-Static Solutions for Site Planning Overview of the N9360A Multi Universal Equipment (UE) Tester Table 3-1. N9360A Tester Functions Table 3-2. Standard Configuration Table 3-3. Accessories Panel Description Table 4-1.
  • Page 7 Legal Information Warranty ..1-2 Technology Licenses ..1-2 Restricted Rights Legend ..1-2 Service And Support ..1-3 Agilent On The Web ..1-3 Agilent By Phone ..1-3 Agilent Technologies...
  • Page 8: Legal Information

    “Restricted computer software” as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies’ standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2)(June 1987).
  • Page 9: Service And Support

    Measurement Assistance Center (81) 0426 56 7832 Latin America: 305 269 7548 Asia-Pacific: (85 22) 599 7777 Manufacturing Address Agilent Technologies Microwave Products (Malaysia) Sdn. Bhd. Bayan Lepas Free Industrial Zone, 11900 Penang, Malaysia. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 10 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK Agilent N9360A Multi UE Tester Installation Guide...
  • Page 11: Safety And Regulatory Information

    Fuses ..2-4 Operator Safety Information ..2-4 Safety Symbols and Regulatory Markings ..2-5 Declaration of Conformity ..2-7 Electrostatic Discharge (ESD) Precautions ..2-9 End of Life: Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC ..2-10 Agilent Technologies...
  • Page 12: Safety Information

    Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies, Inc. assumes no liability for the customer's failure to comply with these requirements. Safety Notice A CAUTION notice denotes a hazard.
  • Page 13: Environmental Conditions

    The protection provided by the N9360A system may be impaired if WARNING the system is used in a manner not specified by Agilent.
  • Page 14: Ground The System

    For example, the inner side of a case, cabinet, door cover or panel can be covered with an insulating material as well as Agilent N9360A Multi UE Tester Installation Guide...
  • Page 15: Safety Symbols And Regulatory Markings

    Terminal is at earth potential. Used for measurement and control circuits designed to be operated with one terminal at earth potential. Terminal for neutral conductor on permanently installed equipment. Terminal for line conductor on permanently installed equipment. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 16 Australian EMC Framework regulations under the terms of the Radio Communications Act of 1992. ISM - 1A This text indicates that the instrument is an Industrial Scientific and Medical Group 1 Class A product (CISPER 11, Clause 4). Agilent N9360A Multi UE Tester Installation Guide...
  • Page 17: Declaration Of Conformity

    IEC 61000-4-11:1994 / EN 61000-4-11:1994 1 cycle / 100% Canada: ICES-001:1998 Australia/New Zealand: AS/NZS 2064.1 The product was tested in a typical configuration with Agilent Technologies test systems. IEC 61010-1:2001 / EN 61010 -1:2001 Safety Canada: CSA C22.2 No. 61010 -1:2004...
  • Page 18 ICES/NMB-001:1998 This ISM device complies with Canadian ICES-001. Cet appareil ISM est confomre à la norme NMB-001 du Canada. Regulatory Information for Australia/New Zealand This ISM device complies with Australian/New Zealand AS/NZS 2064.1 Agilent N9360A Multi UE Tester Installation Guide...
  • Page 19: Electrostatic Discharge (Esd) Precautions

    Electrostatic Discharge (ESD) Precautions Static electricity is destructive to your production process and the N9360A. Careless handling and poor site planning can cause system reliability problems and reduce your product yield. The system may not be as easily damaged as the modules you will be testing, but good anti-static planning will help ensure high reliability.
  • Page 20: End Of Life: Waste Electrical And Electronic Equipment (Weee) Directive 2002/96/Ec

    “Monitoring and Control Instrumentation” product. Do not dispose in domestic household waste To return unwanted products, contact your local Agilent office, or see: http://www.agilent.com/environment/product for more information. 2-10 Agilent N9360A Multi UE Tester Installation Guide...
  • Page 21: Overview Of The N9360A Multi Universal Equipment (Ue) Tester

    Overview of the N9360A Multi Universal Equipment (UE) Tester Introduction ..3-2 System Functions ..3-2 Standard Configuration ..3-5 Power Cord ..3-5 Accessories ..3-7 External Views ..3-7 Agilent Technologies...
  • Page 22: Introduction

    RF performance tests in inpsection processes for mobile phones, service, repairs and maintenence. The N9360A tester uses rf test software to enhance its capability to test multiple radio systems, for example, W-CDMA and GSM/GPRS. This feature provides important cost savings in terms of doing away with different testers as well as saving valuable space.
  • Page 23: Overview Of The N9360A Multi Universal Equipment (Ue) Tester

    Overview of the N9360A Multi Universal Equipment (UE) Tester Table 3-1 N9360A Tester Functions Function Description GSM/GPRS SMS MT SMS MO RF Test Peak TX Power Burst Timing Power Ramp Frequency Error Phase Error (RMS, Peak) BER (GSM) BLER (GPRS)
  • Page 24 Overview of the N9360A Multi Universal Equipment (UE) Tester Table 3-1 N9360A Tester Functions Function Description W-CDMA RF Tests Open Loop Power Control (Open Loop TX Power) Inner Loop Power Control ILP (Down Min) ILP (Down Max) ILP (Up Min)
  • Page 25: Standard Configuration

    Overview of the N9360A Multi Universal Equipment (UE) Tester Standard Configuration Table x shows the standard configuration of the N9360A tester. The user is advised to check the equipment and accessories before using the tester. Table 3-2 Standard Configuration Item Name...
  • Page 26: Figure 3-1 Power Cord Types

    Overview of the N9360A Multi Universal Equipment (UE) Tester Figure 3-1 Power Cord Types Agilent N9360A Multi UE Tester Installation Guide...
  • Page 27: Accessories

    Overview of the N9360A Multi Universal Equipment (UE) Tester Accessories The accessories for the N9360A tester are shown in table x. Contact Sales department of Agilent Technologies, Inc. or a distributor for the specifications of the accessories. Table 3-3 Accessories...
  • Page 28: Figure 3-4 N9360A Rear View

    Overview of the N9360A Multi Universal Equipment (UE) Tester Figure 3-4 N9360A Rear View Figure 3-5 N9360A Side View Agilent N9360A Multi UE Tester Installation Guide...
  • Page 29: Figure 3-6 N9360A Top View

    Overview of the N9360A Multi Universal Equipment (UE) Tester Figure 3-6 N9360A Top View Agilent N9360A Multi UE Tester Installation Guide...
  • Page 30 Overview of the N9360A Multi Universal Equipment (UE) Tester THIS PAGE IS INTENTIONALLY LEFT BLANK 3-10 Agilent N9360A Multi UE Tester Installation Guide...
  • Page 31: Panel Description

    Panel Description Front Panel Rear Panel This chapter provides the description of the front and rear panels of the N9360A Multi Universal Equipment (UE) Tester. Agilent Technologies...
  • Page 32: Front Panel

    CAUTION Agilent approved USB devices to the USB socket. Do not connect any unauthorized devices to the socket. Figure 4-1 shows the front panel of the N9360A tester. The description of the various items indicated is provided in Table 4-1.
  • Page 33: Panel Description

    Agilent does not gurantee the performance of any USB devices. Some NOTE USB memory devices may not operate correctly when inserted into the USB socket. Contact Agilent Sales or approved distributors for a list of approved USB devices. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 34: Rear Panel

    (IEEE 488) USB connector Connector for a USB memory device and a printer. Ethernet connector For external control. (IEEE 802.3) LINE switch Main power ON/OFF switch. Fuse holder Holder for fuses (two 2A). Agilent N9360A Multi UE Tester Installation Guide...
  • Page 35 Panel Description Name Description Remarks AC inlet AC power inlet. Contact Aglients Sales or an approved distributor for a list of CAUTION approved USB memory devices. Not all USB memory devices will work correctly. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 36 Panel Description THIS PAGE IS INTENTIONALLY LEFT BLANK. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 37: Installation

    INSTALLATION Warm Up Time Ventilation AC Power Requirements Agilent Technologies...
  • Page 38: Installation

    14 Avoid blocking the ventilation fan or vent. 15 Make sure the earth cable is connected to the supply earth terminal. 16 Use the tester only in a vibration free environment. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 39: Ac Power Requirements

    4 C for every 100 watts dissipated in the cabinet. If the total power dissipated in the cabinet is greater than 800 watts, then forced convection must be applied. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 40 INSTALLATION THIS PAGE IS INTENTIONALLY LEFT BLANK. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 41: Maintenance, Inspection And Basic Troubleshooting

    Maintenance, Inspection and Basic Troubleshooting Daily Inspection Daily Maintenance Warnings Basic Troubleshooting Repairs and Services Calibration Agilent Technologies...
  • Page 42: Warnings

    Daily maintanence consists of keep the tester free from dust and esuring that the display is clear. Wipe the tester with a damp (but not dripping wet) cloth. Wipe the display with a lint free cloth, damping it if necessary. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 43: Basic Troubleshooting

    Reference IN connector on the screen. the rear panel. Connect 10 MHz reference signal to the Reference IN connector and then reboot the Tester. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 44: Repairs And Services

    Agilent Sales or approved distributor to assist in the repairs and return of the unit: • Product Name, model name and serial number. • Details of the problem encountered. • Customer name, organization name and address, and contact number. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 45: Calibration

    It is recommended that the tester be sent for calibration at least once a year. This is prevent measurement errors due to system drift or components aging. Contact Agilent Sales or approved distributor for more information. Agilent N9360A Multi UE Tester Installation Guide...
  • Page 46 Maintenance, Inspection and Basic Troubleshooting THIS PAGE IS INTENTIONALLY LEFT BLANK Agilent N9360A Multi UE Tester Installation Guide...