N9360A Multi UE Tester CDMA2000 Programming Manual
bit 1 (2) :ILP (Down)
bit 2 (4) :ILP (Up)
bit 3 (8) :Max TX Power
bit 4 (16) :Min TX Power
bit 5 (32) :Frequency Error
bit 6 (64) :Multi-code Rho
bit 7 (128) :Time Offset
bit 8 (256) :Sensitivity/PER1
bit 9 (512) :Sensitivity/PER2
bit 10 (1024) :Abort
Each bit is set to 0 if the test is passed or skipped, or each bit is
set to 1 if the test is fail. If there are no test results, all bits are
set to 1, and the value 4095 is returned.
The value in the parentheses is decimal value for each bit. Refer
to
Setting and Querying the
TESTs:AUTO:RESults:ALL:EXPand?
This query command returns summary of the test results with
the integer value of <int 1>, <int 2> and <int 3>. The
return value of this query command differs depending on the
CDMA mode (MC1X or EVDO).
When CDMA mode is MC1X:
• <int 1> contains test contents currently being executed by
sum of the value of 12 bits as follows:
bit 0 (1) :Location Update
bit 1 (2) :MS Call (Talk)
bit 2 (4) :Talk (From MS Call (Talk))
bit 3 (8) :MS Release (From MS Call (Talk) or Talk)
bit 4 (16) :BS Call (Talk)
bit 5 (32) :Talk (From BS Call (Talk))
bit 6 (64) :BS Release/Handoff (From BS Call (Talk) or Talk)
bit 7 (128) :BS Call (RF Test)
bit 8 (256) :RF Test (From BS Call (RF Test))
Programming Command Reference