Agilent Technologies N5341A Installation Manual

Obsai protocol tester

Advertisement

Quick Links

Agilent
OBSAI Protocol Tester
Installation Guide
Agilent Technologies

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies N5341A

  • Page 1 Agilent OBSAI Protocol Tester Installation Guide Agilent Technologies...
  • Page 2: Manual Part Number

    Printing HIstory D-71034 Boeblingen, Germany Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) Agilent Technologies, Inc. can issue revi- Warranty (November 1995), as applicable in any sions between the product releases to technical data.
  • Page 3 Safety Symbols on Instruments Indicates that antistatic Indicates warning or caution. If you precautions should be taken. see this symbol on a product, you CE compliance marking to the EU must refer to the manuals for Safety and EMC Directives. specific Warning or Caution information to avoid personal injury ISM GRP-1A classification...
  • Page 4: Safety Summary

    Agilent Technologies Inc. assumes no liability for the customer's failure to comply with these requirements. Before operation, review the instrument and manual for safety markings and instructions. You must follow these to ensure safe operation and to maintain the instrument in safe condition.
  • Page 5 Environmental Information Installation Guide...
  • Page 6 About this Guide This guide briefly describes OBSAI Protocol Tester, and explains the tasks and functions required for setting up and starting OBSAI Protocol Tester. Here is how this guide is organized: Introduction Provides a list of equipments supplied, and information on what hardware and software should already be there before you move ahead in this guide.
  • Page 7: Agilent Technologies

    Introduction Equipments Supplied Installation Requirements This chapter provides a list of equipments supplied as part of standard shipment to customer, and information on what hardware and software should already be there before you move ahead in this guide. Agilent Technologies...
  • Page 8 Introduction Equipments Supplied Agilent OBSAI Protocol Tester includes: • N5341A Base Station Link Test Module • N5340A Base Station Test Extension Module • N2X Chassis (2- slot or 4- slot) • The following cables: • RP1 cable • RP3 cable...
  • Page 9: Installation Requirements

    Introduction Installation Requirements Prior to starting the installation process, ensure that all the system requirements to install the software components of OBSAI Protocol Tester are in place. In the following sections, you will learn about the requirements of the Controller and Client PCs. Controller PC Requirements •...
  • Page 10 Introduction Installation Guide...
  • Page 11: Setting Up The Hardware

    Connecting a Chassis to the Controller PC Once all the system requirements are in place, you need to start setting up the hardware for OBSAI Protocol Tester. This requires you to set up basic hardware, such as I/O modules, chassis, and controller PC. Agilent Technologies...
  • Page 12 Setting Up the Hardware Adjusting I/O Modules Inside the Chassis To adjust I/O modules inside a chassis, you need to know how to attach as well as remove them to and from chassis. Attaching an I/O module to the chassis To attach an I/O module to the chassis: Insert the I/O module inside the empty slot and push it to adjust it inside the empty slot.
  • Page 13 Setting Up the Hardware Removing an I/O module from the chassis To remove an I/O module from the chassis: Unscrew the screw locks. Figure 2 Screw locks on the Chassis Pull the extractor levers outside the chassis. Pull out the I/O module to remove it from the chassis. Once you have removed the I/O module from the chassis, hold it by the front panel and metal case, and place it on a hard and flat surface.
  • Page 14 Setting Up the Hardware Setting up the N5341A module Once you have adjusted the modules inside the chassis, set up the N5341A module. Figure 3 N5341A module To set the N5341A module • For RP3- 01 connection: First, ensure that SFP is inserted into the RP3- 01 optical port.
  • Page 15 • For RP1 connection: Do the following: • When you are using N5341A as a Base Station with CCM, connect the RP1 receiver port of DUT to the sync burst out port of the RP1 cable, and connect the RP1 cable to the RP1 port. The reference clock of 30.72 MHz will be available on Sys Clk Out.
  • Page 16 Setting Up the Hardware Connecting a Chassis to the Controller PC After setting up the module, you can connect the chassis to the Controller PC. For this, you can refer to the following arrangements, as applicable: • No LAN interface available: In this situation, you can use the USB network adapter to connect the Controller PC to the master chassis.
  • Page 17 Installation Guide Installing OBSAI Protocol Tester Configuring the Controller PC Installing OBSAI Protocol Tester Setting Up the DHCP Service Once you have set up the hardware, you can start installing the software components that come with the installation CD. Agilent Technologies...
  • Page 18 Installing OBSAI Protocol Tester Configuring the Controller PC You need to configure the Controller PC to enable communication between the Controller and Client PCs for data interchange. In order to configure the Controller PC, you need to set up the FTP service.
  • Page 19 Installing OBSAI Protocol Tester • “To Enable FTP To Install FTP Click Start > Settings > Control Panel. The Control Panel window appears. Double- click the Add/Remove Programs icon. The Add/Remove Programs window appears. Click the Add/Remove Windows Components button. The Windows Components Wizard dialog box appears.
  • Page 20 Installing OBSAI Protocol Tester Installing OBSAI Protocol Tester Once you have prepared the system for installation, you can start installing OBSAI Protocol Tester on it. There are two ways to install OBSAI Protocol Tester. One is to install without using the USB network adapter, and the other is to install using the USB network adapter.
  • Page 21 Installing OBSAI Protocol Tester To remove legacy components, do the following: Click Yes. The uninstallation process starts. Once this process ends, the Uninstall Complete screen of the wizard appears. Click Finish. This takes you back to the Install System Protocol Tester Software page. Repeat Steps 3 and 4.
  • Page 22 Installing OBSAI Protocol Tester Click Next. A message box appears that prompts you to attach the USB network adapter to the Controller PC. Attach the USB network adapter to the Controller PC. Click Yes. A message box, displaying the USB network adapter and DHCP settings, appears.
  • Page 23 Installing OBSAI Protocol Tester Figure 4 Computer Management window Click the System Tools > Device Manager icon under the Tree tab. This displays an expandable list of options in the right panel of the Computer Management window. Expand the Network adapters icon. A list of network adapters attached to your computer is displayed.
  • Page 24 Installing OBSAI Protocol Tester Figure 5 Confirm Device Removal message box Click OK. This uninstalls the USB network adapter. You can now remove the USB network adapter from the computer and assign its IP address to some other device. Installation Guide...
  • Page 25: Configuring The Lan Interface

    Installing OBSAI Protocol Tester Setting Up the DHCP Service DHCP is a communication protocol that lets network administrators centrally manage and automate the assignment of IP addresses in a computer network. DHCP lets a network administrator supervise and distribute IP addresses from a central point and automatically sends a new IP address when a computer is plugged into a different place in the network.
  • Page 26: Configuring Dhcp

    Installing OBSAI Protocol Tester Type in the following information in the IP address, Subnet mask, and Default gateway text boxes. IP address: 10.0.0.1 Subnet mask: 255.0.0.0 Click OK. Click OK. Configuring DHCP To configure DHCP, you need to update the DHCP configuration file (dhcpd.conf), restart the DHCP service, and update the DHCP registry file (dhcpd.reg) and the system registry.
  • Page 27 Installing OBSAI Protocol Tester Select dhcpdNT under the Name column. Click Action > Restart. This assigns IP addresses to the serial I/O modules according to the new settings. To update the DHCP registry file and the system registry Go to the c:\dhcpdnt directory. Open the dhcpd.reg file in a text editor.
  • Page 28 Installing OBSAI Protocol Tester Commenting these statements disables the automatic configuration of the IP addresses. Uncomment the following function for each serial I/O module: #host <hostname for module>{ # hardware ethernet <MAC address of the module>; # fixed-address <ip address to be assigned to this module>;...
  • Page 29: Getting Started

    Agilent OBSAI Protocol Tester Installation Guide Getting Started Starting an OBSAI Session Using OBSAI API - Example This chapter provides information on how to power up the system, and the start and join a new OBSAI session. Agilent Technologies...
  • Page 30 Getting Started Starting an OBSAI Session After installing OBSAI Protocol Tester, find out if it is starting fine. The following procedure tells you about how to power up the system and start a new session. In this section, you will learn: •...
  • Page 31 Getting Started AgtInvoke AgtTestSession OpenSession ObsaiExerciser AGT_SESSION_ONLINE In the above command: AgtInvoke is the primary API command used to interact with • OBSAI Protocol Tester. Its syntax is AgtInvoke <object> <method> <params>. Where, <object> is an object in the OBSAI system, <method>...
  • Page 32 Getting Started Using OBSAI API - Example Once you have created and joined a session, you can start to use the OBSAI api. In this section, you will learn: • Creating a trigger on RP1 range and type Creating a trigger on RP1 range and type Consider that you want to trigger when one of the following condition is true: •...
  • Page 33 Installation Guide...
  • Page 34 Copyright Agilent Technologies 2008 Printed in Germany July 2008 Agilent Technologies...