5
Programming Command Reference
5-68
Inner Loop Power (Down)
CONFigure:CONDition:LIMit:INNErpower:Down <<
<real LO>,<real HI>
CONFigure:CONDition:LIMit:INNErpower:Down?
This command sets the low and high limits for Inner Loop Power
(Down) test in each band set by the
allowable range is from -99.99 to +99.99 (dB) in 0.01 steps.
At preset, this is set to -13.00 (dB) (for the low limit) and -7.00
(dB) (for the high limit).
This query command returns the set low and high limits of Inner
Loop Power (Down) test with real separated by a comma. The
range of the value is same as that of the command parameter.
Inner Loop Power (Up)
CONFigure:CONDition:LIMit:INNErpower:Up <<
<real LO>,<real HI>
CONFigure:CONDition:LIMit:INNErpower:Up?
This command sets the low and high limits for Inner Loop Power
(UP) test in each band set by the
allowable range is from -99.99 to +99.99 (dB) in 0.01 steps.
At preset, this is set to +7.00 (dB) (for the low limit) and
+13.00 (dB) (for the high limit).
This query command returns the set low and high limits of Inner
Loop Power (UP) test with real separated by a comma. The range
of the value is same as that of the command parameter.
Max TX Power
CONFigure:CONDition:LIMit:TXPower:MAXimum <<
<real LO>,<real HI>
CONFigure:CONDition:LIMit:TXPower:MAXimum?
This command sets the low and high limits for Max TX Power test
in each band set by the
allowable range is from -99.99 to +99.99 (dBm) in 0.01
steps. At preset, this is set to +23.00 (dBm) (for the low limit)
and +30.00 (dBm) (for the high limit).
N9360A Multi UE Tester CDMA2000 Programming Manual
Band
command. The
Band
command on
Band
command on
page
page
36. The
36. The