Agilent Technologies, Inc. as governed by United States and international copyright laws. N9360A Multi UE Tester Quick Reference Guide Manual Part Number N9360-90002 Edition Third Edition, March 2008...
Page 3
• The manual includes the the tester operation, test procedures and screen references. • Refer to the N9360A Multi UE Tester Installation Guide for information regarding installation and details of the tester. Refer also to the N9360A W-CDMA Option User Manual and N9360A cdma2000 Option...
Page 4
THIS PAGE IS INTENTIONALLY LEFT BLANK. N9360A Multi UE Tester Quick Reference Guide...
Contents Legal Information Caution and Safety Requirements General Operation GSM System N9360A Multi UE Tester Quick Reference Guide Notation I-iii Notices I-iii Trademarks I-iii Legal Information Warranty Technology Licenses Restricted Rights Legend Service And Support Agilent On The Web Agilent By Phone...
Page 6
RX Quality 4-10 For Go/No-Go Testing For Pinpointing Failures For Troubleshooting UARFCN Mobile Phone Maximum Output Power When "CDMA Mode" is set to MC-1x mode When "CDMA Mode" is set to 1xEV-DO mode N9360A Multi UE Tester Quick Reference Guide...
Legal Information Warranty Technology Licenses Restricted Rights Legend Service And Support Agilent On The Web Agilent By Phone Agilent Technologies...
Restricted Rights as defined in FAR 52.227-19(c)(1-2)(June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2)(November 1995), as applicable in any technical data. N9360A Multi UE Tester Quick Reference Guide...
Service And Support Agilent On The Web Agilent By Phone N9360A Multi UE Tester Quick Reference Guide Any adjustment, maintenance, or repair of this product must be performed by qualified personnel. Contact your customer engineer through your local Agilent Technologies Service Center.
Page 10
Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK N9360A Multi UE Tester Quick Reference Guide...
Page 11
Caution and Safety Requirements Safety Summary Safety Notices Warning Label General When Operating The Tester Agilent Technologies...
Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. A warning label is stuck on the front panel of the Tester. Do not remove, damage or modify the warning label. N9360A Multi UE Tester Quick Reference Guide...
C A U T I O N N9360A Multi UE Tester Quick Reference Guide The protection provided by the N9360A tester may be impaired if the tester is used in a manner not specified by Agilent or the instructions on the display are not followed.
Page 14
Caution and Safety Requirements THIS PAGE IS INTENTIONALLY LEFT BLANK. N9360A Multi UE Tester Quick Reference Guide...
General Operation Using a USB memory device Using the Knob on the Front Panel Preparation for Tests GSM/W-CDMA/cdma2000 Mobile Phone Repair Process Agilent Technologies...
[Configuration] screen to a screen image into a USB memory device, press the Print Screen softkey. The file format is PNG (Portable Network Graphics). N9360A Multi UE Tester Quick Reference Guide . Then, to save USB Memory 2.
Preparation for Tests N9360A Multi UE Tester Quick Reference Guide Figure 3-1 Typical Test Setup Connecting RF Signal: Connect the mobile phone to the Tester using the user-supplied RF Cable, optional Antenna Coupler, or optional Shield Case. On the [Loss] screen obtained from the [Initial], [Configuration] and [Configuration: Test Condition] screens, set the “Loss”...
Incoming Inspection and Mechanical & Module Repair. In each process, you can perform the following tests with the Agilent N9360A Multi UE Tester. Table 3-1 Mobile Phone Repair Function Process...
GSM System For Go/No-Go Testing For Pinpointing Failures For Troubleshooting RF Channels MS Power Control / Power Class RX Level RX Quality 4-10 Agilent Technologies...
After completing the test, check the results on the screen. To print the test results or to save them into a USB memory device, press the More (1 of 2) softkey and then the Print Screen softkey. N9360A Multi UE Tester Quick Reference Guide...
For Pinpointing Failures N9360A Multi UE Tester Quick Reference Guide Table 4-2 GSM Automatic test sequence Step Action needed Location Update Wait until the Location Update is complete. MS Call Dial an arbitrary number and press the Off Hook key on the mobile phone.
Page 22
Phase Error Frequency Error Figure 4-3 Various [Automatic Test: Stand-by] Screens To display other measurement result screens or to finish analysis, press the Return softkey to display the previous screen. N9360A Multi UE Tester Quick Reference Guide Peak TX Power...
For Troubleshooting N9360A Multi UE Tester Quick Reference Guide Figure 4-4 [Manual Test (GSM): Stand-by] Screen Press the Manual Test softkey on the [Initial] screen. Move the cursor to the “Procedure” field and select a pre-defined test procedure. Turn the mobile phone on.
Page 24
Spectrum Monitor softkey to display a measurement result screen according to your selection. Then, press the Trigger softkey to start single measurement or Trigger Sing/Cont softkey to start continuous measurement. N9360A Multi UE Tester Quick Reference Guide Peak TX Power/ Burst Timing/ Power Ramp...
Power Control Nominal Power Level (dBm) N9360A Multi UE Tester Quick Reference Guide Press the Trigger Sing/Cont softkey again to terminate the continuous measurement. In the graphical display, the marker function is available to read the data points by rotating the knob. On the power ramp graph display, the zoom function is also available.
Page 26
Power Class Max Power Control Level DCS1800 Power Control Nominal Power Level (dBm) DCS1800 Power Class Max Power Control Level N9360A Multi UE Tester Quick Reference Guide PCS1900 Power Control Nominal Power Level (dBm) PCS1900 Power Class Max Power Control Level...
–94 to –93 dBm –93 to –92 dBm –92 to –91 dBm –91 to –90 dBm –90 to –89 dBm N9360A Multi UE Tester Quick Reference Guide RX Level –89 to –88 dBm –88 to –87 dBm –87 to –86 dBm –86 to –85 dBm...
RX Quality <0.2 % 0.2 to 0.4 % 0.4 to 0.8 % 0.8 to 1.6 % 4-10 RX Quality 1.6 to 3.2 % 3.2 to 6.4 % 6.4 to 12.8 % >12.8 % N9360A Multi UE Tester Quick Reference Guide...
Page 29
W-CDMA System For Go/No-Go Testing For Pinpointing Failures For Troubleshooting UARFCN Mobile Phone Maximum Output Power Agilent Technologies...
After completing the test, check the results on the screen. To print the measurement results or to save them into a USB memory device, press the More (1 of 2) softkey and then the Print Screen softkey. N9360A Multi UE Tester Quick Reference Guide...
For Pinpointing Failures N9360A Multi UE Tester Quick Reference Guide Table 5-1 W-CDMA Automatic Test Sequence Step Action needed Location Update Wait until the Location Update is completed. MS Call Dial an arbitrary number and press the Off Hook key on the mobile phone.
Trigger softkey to start single measurement or the Trigger Sing/Cont softkey to start continuous measurement. Press the Trigger Sing/Cont softkey again to terminate continuous measurement. Press the Release softkey to finish the Test. N9360A Multi UE Tester Quick Reference Guide...
(dB) Band I +1/–3 Band II Band III Band IV Band V Band VI Band VIII N9360A Multi UE Tester Quick Reference Guide Additional General — 10562 to 10838 9662 to 9938 212, 237, 262, 287 — 9037 to 9388...
Page 34
W-CDMA System THIS PAGE IS INTENTIONALLY LEFT BLANK. N9360A Multi UE Tester Quick Reference Guide...
After completing the test, check the results on the screen. To print the test results or to save them into a USB memory device, press the More(1 of 2) softkey and then the Print Screen softkey. N9360A Multi UE Tester Quick Reference Guide...
Page 37
N9360A Multi UE Tester Quick Reference Guide Table 6-1 cdma2000 Automatic Test Sequence Step Action Needed Location Update Wait until the Location Update is complete. MS Call (Talk) Dial an arbitrary number and press the Off Hook key on the mobile phone.
Page 38
For Pinpointing Failures Figure 6-2 [Auto Test (MC-1x): Stand-by] Screen Perform the steps described in "For Go/No-Go Testing.” Press the Screen>> softkey to set screen mode to Value. Check the values of the measurement results. N9360A Multi UE Tester Quick Reference Guide...
Page 39
N9360A Multi UE Tester Quick Reference Guide For Troubleshooting Figure 6-3 [Manual Test (MC-1x): Stand-by] Screen Press the Manual Test softkey on the [Initial] screen. Move the cursor to the "Procedure" field and select a pre-defined test procedure. Set the Service Option field to 32.
After completing the test, check the results on the screen. To print the test results or to save them into a USB memory device, press the More(1 of 2) softkey and then the Print Screen softkey. N9360A Multi UE Tester Quick Reference Guide...
Page 41
N9360A Multi UE Tester Quick Reference Guide Table 6-2 1xEVDO Automatic Test Sequence Step Action Needed UATI Assignment Wait until the UATI Assignment is completed. BS Call The mobile phone automatically responds to the call. RF Test Wait until the RF test is completed.
Page 42
Trigger softkey to start single measurement or the Trigger Sing/Cont softkey to start continuous measurement. Press the Trigger Sing/Cont softkey again to terminate continuous measurement. Press the Release softkey to finish the test. N9360A Multi UE Tester Quick Reference Guide...
Page 43
N9360A Multi UE Tester Quick Reference Guide RF Channel Table 6-3 cdma2000 Frequency Band Radio System BAND0: CEL US BAND1: PCS US BAND3: Cel JP BAND4: PCS KR BAND6: IMT-2K † The BAND15: AWS is available only when the Option C03 is installed in the Tester.
Page 44
System THIS PAGE IS INTENTIONALLY LEFT BLANK. 6-10 N9360A Multi UE Tester Quick Reference Guide...