Table 6-15 Command Cross Reference for [Stand-by] Screen (continued)
Item
Service Option
Radio Configuration
Power Control Level
PER FT Rate
FER Max Frames
FER Confidence
PER Max Packets
PER Confidence
Caller ID
Averaging
SCH Rate
SCH Encoder
SCH Level
Call Drop Timer
Network ID
System ID
Network ID (for Zone-based
Registration)
N9360A Multi UE Tester CDMA2000 Programming Manual
Command
TEST:MAN:SOPT <enum>
TEST:MAN:SOPT?
TEST:MAN:RCON F1R1|F2R2|F3R3|F4R3|F5R4
TEST:MAN:RCON?
TEST:MAN:PLEV UP|DOWN|CNTUP|CNTDWN|HOLD, <int>
TEST:MAN:PLEV?
TEST:MAN:FTRA 307.2|2457.6|3072.0
TEST:MAN:FTRA?
TEST:MAN:FER:MAXF <int>
TEST:MAN:FER:MAXF?
TEST:MAN:FER:CONF 95%|OFF
TEST:MAN:FER:CONF?
TEST:MAN:PER:MAXP <int>
TEST:MAN:PER:MAXP?
TEST:MAN:PER:CONF 95%|OFF
TEST:MAN:PER:CONF?
TEST:MAN:CALL:ID <string>
TEST:MAN:CALL:ID?
TEST:MAN:CALL:ID:SEND ON|OFF|1|0
TEST:MAN:CALL:ID:SEND?
TEST:MAN:AVER OFF|<int>
TEST:MAN:AVER?
TEST:MAN:SCH:DRAT <enum>
TEST:MAN:SCH:DRAT?
TEST:MAN:SCH:ENC <enum>
TEST:MAN:SCH:ENC?
TEST:MAN:SCH:LEV <real>
TEST:MAN:SCH:LEV?
TEST:MAN:CDT ON|OFF|1|0
TEST:MAN:CDT?
TEST:MAN:NID <int>
TEST:MAN:NID?
TEST:MAN:SID <int>
TEST:MAN:SID?
TEST:MAN:RNID <int>
TEST:MAN:RNID?
Programming Command Summary