This query command returns the set low and high limits of Max
TX Power test with real separated by a comma. The range of the
value is same as that of the command parameter.
Min TX Power
CONFigure:CONDition:LIMit:TXPower:MINimum <<
<real LO>,<real HI>
CONFigure:CONDition:LIMit:TXPower:MINimum?
This command sets the low and high limits for Min TX Power test
in each band set by the
allowable range is from -99.99 to +99.99 (dBm) in 0.01
steps. At preset, this is set to -99.99 (dBm) (for the low limit)
and -50.00 (dBm) (for the high limit).
This query command returns the set low and high limits of Min
TX Power test real separated by a comma. The range of the value
is same as that of the command parameter.
Frequency Error
CONFigure:CONDition:LIMit:FREQuency <<
<real LO>,<real HI>
CONFigure:CONDition:LIMit:FREQuency?
This command sets the low and high limits for Frequency Error
test in each band set by the
allowable range is from -10000.0 to +10000.0 (Hz) in 0.1
steps. At preset, this is set to -300.0 (Hz) (for the low limit)
and +300.0 (Hz) (for the high limit).
This query command returns the set low and high limits of
Frequency Error test with real separated by a comma. The range
of the value is same as that of the command parameter.
Rho
CONFigure:CONDition:LIMit:RHO <real LO>,<<
<real HI>
CONFigure:CONDition:LIMit:RHO?