Available Functions For Aux Output Ports - Kenwood NX-5000 Series Common Function Reference

Hide thumbs Also See for NX-5000 Series:
Table of Contents

Advertisement

11 EXTERNAL PORTS
11.2 D-sub 25-pin Connector

Available Functions for AUX Output Ports

The following functions can be assigned to AUX Output ports:
Function Name
None
No function is assigned.
For a Conventional Channel (Analog/ NXDN/ DMR/ P25):
For an LTR Trunking system:
For a P25 Trunking system:
LOK
For an NXDN Trunking system:
The output signal of LOK can be configured using KPG-D1/ D1N. There are 2 types of LOK Logic
Signals: "Continuous" and "Pulse". The port is always at low level while the LOK port is active if
"Continuous" is selected. The LOK port is active for the first 30 ms, and then the LOK port returns
to open level if "Pulse" is selected.
For a Conventional Channel (Analog/ NXDN/ DMR/ P25) or an LTR Trunking system:
For a P25 Trunking system:
COR
For an NXDN Trunking system:
The COR or Channel Busy output port is active while the conditions to activate COR or the
COR or Channel Busy
conditions to activate Channel Busy are satisfied. While conditions to activate COR and Channel
Busy are not satisfied, the COR or Channel Busy output port is inactive.
For a Conventional Channel (Analog/ NXDN/ P25):
For a Conventional Channel (DMR):
TOR
For an LTR Trunking system:
For a P25 Trunking system and NXDN Trunking system:
Common FUNC (K, F)/Ver 2.20
Table 11-8 Available Functions for AUX Output Ports
The output port is active while the transceiver is transmitting. Otherwise, the output port is
inactive.
The output port is activated when the transceiver is linked with a repeater while transmitting.
Otherwise, the output port is inactive.
The output port is active while the transceiver is transmitting on a traffic channel. Otherwise, the
output port is inactive.
This function applies to all audio and data communications on the traffic channel.
The output port is active while the transceiver is transmitting on a traffic channel. Otherwise, the
output port is inactive.
The output port is active while the transceiver is receiving a carrier. Otherwise, the output port
is inactive.
The output port is active while the transceiver is receiving a carrier. Otherwise, the output port
is inactive.
All carriers as well as P25 signals are targeted.
The output port is active while the transceiver is receiving a carrier. Otherwise, the output port
is inactive.
The output port is active while the received QT tone or DQT code (Analog), RAN code (NXDN),
or NAC (P25) matches the QT tone or DQT code (Analog), RAN code (NXDN), or NAC (P25)
preconfigured for the transceiver. If QT/DQT Decode is not configured, the output port is active
while the transceiver is receiving a carrier. If RAN Decode is not configured, the output port is
active while the transceiver is receiving a RAN code. Otherwise, the output port is inactive.
The output port is active while the transceiver is unmuting the speaker. Otherwise, the output
port is inactive.
The output port is active while a Group ID is received. Otherwise, the output port is inactive.
The output port is active while the transceiver is unmuting the speaker on a traffic channel.
Otherwise, the output port is inactive.