Language Reference
[:SENSe]:EBWidth Subsection
Emission BW Trace Max Hold On/Of f
[ :
SENSe] : EBWidth:MAXHold OFF~ON~0~ 1
[ :SENSe] :EBWidth :MAXHold?
Turn on or off the trace max hold trace feature for emission bandwidth
measurements .
Factory Preset
and *RST:
On
Remarks:
This command is used for measurements in th e
MEASURE
menu. Max hold on displays and holds the
maximum responses of a signal ; max hold off disables
the feature.
Front Panel
Access :
Meas Setup, Max Hold On Of f
Set Emission BW X dB Value
[ :SENSe] :EBWidth :XDB <rel ampl>
[ :SENSe] :EBWidth :XDB?
This commands allows you to set the dB value (X dB) below th e
maximum value on the signal at which to measure the emissio n
bandwidth.
Range :
Only negative values are allowed .
Default Unit : dB
Remarks :
This command is used for measurements in the
MEASURE
menu .
Front Pane l
Access :
Meas Setup, Emiss BW X d B
Chapter 5
5-99