5.10 o: Operator Related Settings

These parameters concern the various functions and features of the digital operator.
o1: Display Settings and Selections
u
These parameters determine how data is shown on the operator display.
o1-01: Drive Mode Unit Monitor Selection
n
When using an LED operator, pressing the up arrow key on the drive will display the following data: frequency reference →
rotational direction → output frequency → output current → o1-01 selection.
Parameter o1-01 selects the content of the last monitor in this sequence. There is no effect like this on an LCD operator.
No.
o1-01
<1> U2-oo and U3-oo parameters cannot be selected.
To select a monitor parameter, set the three numeric digits that make up that monitor. This is done by entering the o-oo part
of Uo-oo.
o1-02: User Monitor Selection after Power Up
n
Selects which monitor parameter will be displayed upon power up. Defaulted to show the frequency reference when the drive
is first turned on.
No.
o1-02
Setting 1: Frequency Reference (U1-01)
Setting 2: Forward/Reverse
Setting 3: Output Frequency (U1-02)
Setting 4: Output Current (U1-03)
Setting 5: User Selected Monitor (set by o1-01)
Setting 5 displays the monitor selected from the U parameter by o1-01.
o1-03: Digital Operator Display Selection
n
Sets the units used to display the frequency reference and output frequency.
Set this parameter to 3 for user-set units before setting parameters o1-10 and o1-11.
No.
o1-03
Setting 0: 0.01 Hz Units
Setting 1: 0.01% Units
100% = max output frequency.
Setting 2: r/min Units
Calculated by the max output frequency and the number of motor poles.
Note:
Setting 2 requires entering the number of motor poles to E2-04, E4-04, and E5-04.
Setting 3: User-Set Units (use o1-01 and 01-11)
Set the value used for the maximum frequency reference to o1-10, then set the placement of the decimal point in this number
to o1-11.
For example, to display the maximum output frequency as "100.00", set o1-10 to 10000 and o1-11 to 2 (i.e., 10000 with two
numbers to the right of the decimal point).
Note:
Parameter o1-03 allows the programmer to change the units used in the following parameters and monitors:
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Name
Drive Mode Unit Monitor Selection
Name
User Monitor Selection after Power Up
Name
Digital Operator Display Selection
5.10 o: Operator Related Settings
Setting Range
104 to 904
<1>
(U1-04 to U9-04)
Setting Range
1 to 5
Setting Range
0 to 3
Default
106 (U1-06)
Default
1
Default
0
5
215