B.11 o: Operator Related Parameters
No.
(Addr.
Name
Hex)
o1-10
User-Set Display Units
(0520)
Maximum Value
o1-11
User-Set Display Units
(0521)
Decimal Display
o1-12
(0522)
Home Help Text
<1> Default setting is dependent on parameter o1-03, Digital Operator Display Selection.
o2: HOA Keypad Keypad Functions
u
No.
(Addr.
Name
Hex)
o2-02
STOP Key Function
(0506)
Selection
o2-03
User Parameter Default
(0507)
Value
o2-04
Drive Model Selection
(508)
Frequency Reference
o2-05
Setting Method
(0509)
Selection
Operation Selection
o2-06
when Digital Operator is
(050A)
Disconnected
Motor Direction at
o2-07
Power Up when Using
(0527)
Operator
o2-30
(1230)
Monitor Position Save
o3: Copy Function
u
No.
(Addr.
Name
Hex)
o3-01
Copy Function
(0515)
Selection
o3-02
Copy Allowed Selection
(0516)
354
LCD Display
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output
UserDisp Scaling
frequency.
o1-11 sets the position of the decimal position.
UserDisp Dec
Switches the top line of the Home Screen from the Drive Status
Top Help on Home
to defined Help messages.
0: Disabled
0: Disabled
1: Enabled
1: Enabled
LCD Display
Oper STOP Key
0: Disabled. STOP key is disabled in REMOTE operation.
0: Disabled
1: Enabled. STOP key is always enabled.
1: Enabled
0: No change.
User Default Sel
1: Set defaults. Saves parameter settings as default values for a
0: No Change
User Initialization.
1: Save User Init
2: Clear all. Clears the default settings that have been saved for
2: Clear User Init
a User Initialization.
Enter the drive model. Setting required only if installing a new
Inverter Model #
control board.
Oper Ref Method
0: ENTER key must be pressed to enter a frequency reference.
0: Disabled
1: ENTER key is not required. The frequency reference can be
1: Enabled
adjusted using the up and down arrow keys only.
Oper Discon Det
0: The drive continues operating if the digital operator is
0: Disabled
disconnected.
1: Enabled
1: An oPr fault is triggered and the motor coasts to stop.
This parameter requires assigning drive operation to the digital
For/RevSel@PwrUp
operator.
0: Forward
0: Forward
1: Reverse
1: Reverse
Saves the monitor position and Home Screen quick monitor
selection.
Mon Pos Save
Setting this parameter to 0 and then entering the Monitor Menu
0: Disabled
will jump the selection to the monitor number instead of the
1: Enabled
group number.
0: Disabled
1: Enabled
LCD Display
0: No action
COPY SELECT
1: Read parameters from the drive, saving them onto the digital
0: COPY SELECT
operator.
1: INV→OP READ
2: Copy parameters from the digital operator, writing them to
2: OP→INV WRITE
the drive.
3: OP←→INV
3: Verify parameter settings on the drive to check if they match
VERIFY
the data saved on the operator.
Read Allowable
0: Read operation prohibited
0: Disabled
1: Read operation allowed
1: Enabled
Description
Description
Description
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Values
Page
<1>
Default:
217
Range: 1 to
60000
<1>
Default:
217
Range: 0 to 3
Default: 1
217
Range: 0, 1
Values
Page
Default: 1
217
Range: 0, 1
Default: 0
218
Range: 0 to 2
Default:
Determined by
218
drive capacity
Default: 0
218
Range: 0, 1
Default: 0
219
Range: 0, 1
Default: 0
219
Range: 0, 1
Default: 0
219
Range: 0, 1
Values
Page
Default: 0
219
Range: 0 to 3
Default: 1
220
Range: 0, 1