YASKAWA iQpump Micro CIMR-PW Series User Manual page 362

Ac drive compact intelligent pump controller
Table of Contents

Advertisement

B.12 P: Pump Parameters
No.
(Addr.
Name
Hex)
P5-05
(0D30) HAND Reference 2
P5-06
(0D31) HAND Ref. 1 Loss of
Prime Level
P5-07
(0D32) HAND Ref. 2 Loss of
Prime Level
HAND References Set
P5-09
via Motor Operated Pot
(0D34)
Selection
<1> Unit text is set by P1-18, Prime Loss Detection Method.
P7: Anti-Jam
u
No.
(Addr.
Name
Hex)
P7-01
Anti-Jam Operation
(0D90)
Selection
P7-02
(0D91) Anti-Jam Cycle Count
P7-03
(0D92) Anti-Jam Detection
Current Level
P7-04
(0D93) Anti-Jam Detection
Time at Start
P7-05
(0D94) Anti-Jam During Run
Current
P7-06
(0D95) Anti-Jam During Run
Time
P7-07
(0D96) Anti-Jam Frequency
Reference
P7-08
(0D98) Anti-Jam Release Time AJ Release Time
P9: Network Options
u
Parameters in this group are functional only when P1-01, Pump Mode, is set to 3 (MEMOBUS network).
362
LCD Display
Sets the frequency reference used when HAND Mode 2 is
active.
HAND Reference 2
Detects loss of prime in the pump when in HAND Mode.
When the measured quantity determined by P1-18 drops below
this level for the time set in P1-20 and the output frequency is
HandRef1 LOP Lvl
at the level set in P5-02, a "Loss of Prime" condition occurs.
The drive responds to the "Loss of Prime" condition depending
on the setting of P1-22, Loss of Prime Selection.
Detects loss of prime in the pump when in HAND Mode 2.
When the measured quantity determined by P1-18 drops below
this level for the time set in P1-20 and the output frequency is
HandRef2 LOP Lvl
at the level set in P5-05, a "Loss of Prime" condition occurs.
The drive responds to the "Loss of Prime" condition depending
on the setting of P1-22, Loss of Prime Selection.
Selects whether parameters P5-02 and P5-05 are changed via
HAND MOP Sel
MOP from the home screen.
0: Disabled
0: Disabled
1: Enabled
1: Enabled
LCD Display
Anti-Jam Sel
Enables and disables the anti-jam function.
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Sets the maximum number of cycles that will be attempted
before triggering and Anti-Jam fault.
AJ Cycle Count
Sets the current level at start that will trigger the anti-jam
function.
AJ Det I @Start
Set as a percentage of the motor rated current.
Sets the length of time that current must rise above the level set
in P7-03 to trigger the anti-jam function.
AJ Det Tm@Start
Sets the current level during run that will trigger the anti-jam
function.
AJ Det I @Run
Set as a percentage of motor rated current.
Setting this parameter to 0 will disable anti-jam during run.
Sets the length of time that the current must rise above the level
AJ Det Tm @Run
set in P7-05 to trigger the anti-jam function.
Restricted to simplex only.
Sets the maximum speed allowed when the anti-jam function is
active.
AJ Freq Ref
Sets the length of time that the current must fall below the level
set in P7-03 to resume normal operation.
Description
Description
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Values
Page
Default: 0.0 Hz
236
Min.: 0.0
Max.: [E1-04]
Default: 0.0 A
<1>
236
Min.: 0.0
Max.: 1000.0
Default: 0.0 A
<1>
236
Min.: 0.0
Max.: 1000.0
Default: 0
236
Range: 0, 1
Values
Page
Default: 0
237
Range: 0, 1
Default: 1
237
Min.: 1
Max.: 100
Default: 120%
237
Min.: 50
Max.: 200
Default: 0.3 s
237
Min.: 0.1
Max.: 2.0
Default: 0%
Min.: 0
237
Max.: 200
Default: 0.3 s
Min.: 0.1
237
Max.: 2.0
Default: 25.00
Hz
237
Min.: 0.00
Max.: 400.00
Default: 2.0 s
237
Min.: 0.5
Max.: 10.0