YASKAWA iQpump Micro CIMR-PW Series User Manual page 374

Ac drive compact intelligent pump controller
Table of Contents

Advertisement

B.16 U: Monitors
No.
(Addr.
Name
Hex)
U3-43
Date Month and Day
8th at Most Recent Fault Fault 8 MMDD
(3021)
Time Hours and
U3-44
Minutes at 8th Most
(3022)
Recent Fault
U3-45
Date Year at 9th Most
(3023)
Recent Fault
U3-46
Date Month and Day at
(3024)
9th Most Recent Fault
Time Hours and
U3-47
Minutes at 9th Most
(3025)
Recent Fault
U3-48
Date Year at 10th Most
(3026)
Recent Fault
U3-49
Date Month and Day at
(3027)
10th Most Recent Fault
Time Hours and
U3-50
Minutes at 10th Most
(3028)
Recent
U4: Maintenance Monitors
u
No.
(Addr.
Name
Hex)
U4-01
Cumulative Operation
(004C)
Time
<1>
U4-02
Number of Run
(0075)
Commands
U4-03
Cooling Fan Operation
(0067)
Time
<2>
U4-04
Cooling Fan
(007E)
Maintenance
U4-05
Capacitor Maintenance Cap Life Mon
(007C)
U4-06
Soft Charge Bypass
(07D6)
Relay Maintenance
U4-07
IGBT Maintenance
(07D7)
U4-08
Heatsink Temperature
(0068)
U4-09
LED Check
(003C)
374
LCD Display
Displays the date and day when the eighth most recent fault
occurred.
Fault 8 HHMM
Displays the time when the eighth most recent fault occurred.
Fault 9 YYYY
Displays the year when the ninth most recent fault occurred.
Displays the date and day when the ninth most recent fault
Fault 9 MMDD
occurred.
Fault 9 HHMM
Displays the time when the ninth most recent fault occurred.
Fault 10 YYYY
Displays the year when the tenth most recent fault occurred.
Displays the date and day when the tenth most recent fault
Fault 10 MMDD
occurred.
Fault 10 HHMM
Displays the time when the tenth most recent fault occurred.
LCD Display
Displays the cumulative operation time of the drive. The value
for the cumulative operation time counter can be reset in
parameter o4-01. Use parameter o4-02 to determine if the
Drv Elapsed Time
operation time should start as soon as the power is switched on
or only while the Run command is present. The maximum
number displayed is 99999, after which the value is reset to 0.
Displays the number of times the Run command is entered.
Reset the number of Run commands using parameter o4-13.
RUN Cmd Counter
This value will reset to 0 and start counting again after reaching
65535.
Displays the cumulative operation time of the cooling fan. The
default value for the fan operation time is reset in parameter
Fan Elapsed TIme
o4-03. This value will reset to 0 and start counting again after
reaching 99999.
Displays main cooling fan usage time as a percentage of its
expected performance life. Parameter o4-03 can be used to reset
Fan Life Mon
this monitor.
Replace the fan when this monitor reaches 90%.
Displays main circuit capacitor usage time as a percentage of
their expected performance life. Parameter o4-05 can be used
to reset this monitor.
Replace the capacitor when this monitor reaches 90%.
Displays the soft charge bypass relay maintenance time as a
percentage of its estimated performance life. Parameter o4-07
ChgCirc Life Mon
can be used to reset this monitor.
Replace the soft charge bypass relay when this monitor reaches
90%.
Displays IGBT usage time as a percentage of the expected
performance life. Parameter o4-09 can be used to reset this
IGBT Life Mon
monitor.
Replace the IGBT when this monitor reaches 90%.
Displays the heatsink temperature.
Heatsink Temp
Lights all segments of the LED to verify that the display is
LED Oper Check
working properly. Press the ENTER key to turn the LEDs on
and press ESC to turn the LEDs off.
Description
Description
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Analog
Unit
Output Level
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
Analog
Unit
Output Level
No signal output
1 h
available
No signal output
1 Time
available
No signal output
1 h
available
No signal output
1%
available
No signal output
1%
available
No signal output
1%
available
No signal output
1%
available
10 V: 100 °C
1 °C
No signal output
available

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents