B.17 Defaults by Drive Model
Table B.4 Three-Phase, 200 V Class Drives Default Settings by Drive Capacity
No.
o2-04
E2-11
b3-06
Speed Search current 1
Current Control Gain during Speed Search (Speed
b3-08
Estimation Type)
C6-02
Carrier frequency
E2-01
Motor rated current
E2-02
Motor rated slip
E2-03
Motor no-load current
E2-05
Motor line-to-line resistance
E2-06
Motor leakage inductance
E2-10
Motor Iron Loss
L2-02
Momentary power loss ride-through time
L2-03
Momentary power loss Baseblock time
L2-04
Momentary power loss voltage recovery time
L2-05
Uv detection voltage
L3-24
Motor acceleration time
L8-02
Overheat alarm level
L8-09
Ground fault selection
L8-38
Carrier frequency reduction selection
n1-03
Hunting Prevention Time Constant
378
Description
Model
Drive Model Selection
Motor Rated Power
Unit
2V0006
2V0010
Hex
63
65
kW
1.1
2.2
0.5
0.5
0.5
0.5
7
7
A
4.9
8.5
Hz
2.6
2.9
A
2.3
3.0
Ω
3.577
1.601
%
18.5
18.4
W
38
77
s
0.2
0.3
s
0.4
0.5
s
0.3
0.3
V dc
190
190
s
0.142
0.145
°C
100
100
0
0
1
1
ms
10
10
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Default Settings
2V0012
2V0020
66
68
3.0
5.5
0.5
0.5
0.5
0.5
7
7
11.4
19.6
2.7
1.5
3.7
5.1
1.034
0.399
19
18.2
91
172
0.5
1
0.5
0.7
0.3
0.6
190
190
0.145
0.168
100
110
0
0
1
1
10
10
2V0030
6A
7.5
0.5
0.5
7
26.6
1.3
8.0
0.288
15.5
262
1.0
0.8
0.6
190
0.175
115
1
2
10