D.3 UL and CSA Standards
UL Standards Compliance
u
The UL/cUL mark applies to products in the United States and Canada and indicates that UL has performed product testing
and evaluation and determined that their stringent standards for product safety have been met. For a product to receive UL
certification, all components inside that product must also receive UL certification.
This drive is tested in accordance with UL standard UL508C and complies with UL requirements. The following conditions
must be met to maintain compliance when using this drive in combination with other equipment:
Installation Area
n
Do not install the drive to an area greater than pollution severity 2 (UL standard).
Ambient Temperature
n
IP20/NEMA 1, UL Type 1 enclosure: -10 °C to +40 °C (14 °F to 104 °F)
IP20/IP00 Open-Chassis enclosure: -10 °C to +50 °C (14 °F to 122 °F)
Main Circuit Terminal Wiring
n
Yaskawa recommends using closed-loop crimp terminals on all drive models. UL/cUL approval requires the use of UL Listed
closed-loop crimp terminals when wiring the drive main circuit terminals. Use only the tools recommended by the terminal
manufacturer for crimping. The wire gauges listed in
Refer to local codes for proper wire gauge selections.
Drive
Model
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
BA0001
BA0002
, 1, 2
BA0003
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
, 1, 2
BA0006
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
BA0010
, 1, 2
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
, 1, 2
BA0012
B1, B2
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Figure D.4 UL/cUL Mark
Table
Table D.6 Wire Gauge and Torque Specifications
Terminal
D.6,
Table
D.7, and
Table D.8
Recomm.
Wire Range
Gauge
AWG, kcmil
AWG, kcmil
14
18 to 14
14
18 to 14
18 to 14
18 to 14
14
18 to 14
12
14 to 10
14
14 to 10
14 to 10
14 to 10
10
14 to 10
10
14 to 10
14
14 to 10
14 to 10
14 to 10
10
14 to 10
10
14 to 10
14
14 to 10
14 to 10
14 to 10
10
14 to 10
D.3 UL and CSA Standards
are Yaskawa recommendations.
Tightening
Screw
Torque
Size
N•m (lb.in.)
0.8 to 1.0
M3.5
(7.1 to 8.9)
1.2 to 1.5
M4
(10.6 to 13.3)
1.2 to 1.5
M4
(10.6 to 13.3)
2.3 to 2.5
M4
(20.4 to 22.1)