o4: Maintenance Monitor Settings
u
No.
(Addr.
Name
Hex)
o4-01
Cumulative Operation
(050B)
Time Setting
o4-02
Cumulative Operation
(050C)
Time Selection
o4-03
Cooling Fan Operation
(050E)
Time Setting
o4-05
Capacitor Maintenance
(051D)
Setting
DC Bus Pre-Charge
o4-07
Relay Maintenance
(0523)
Setting
o4-09
IGBT Maintenance
(0525)
Setting
o4-11
U2, U3 Initialization
(0510)
o4-12
kWh Monitor
(0512)
Initialization
Number of Run
o4-13
Commands Counter
(0528)
Initialization
o4-17
Set/Reset Real-Time
(3100)
Clock
o4-20
Time Display Format
(081F)
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
LCD Display
Sets the value for the cumulative operation time of the drive in
DrvElapsTimeCnt
units of 10 h.
ElapsTimeCntSet
0: Logs power-on time
0: Power-On Time
1: Logs operation time when the drive output is active (output
1: Running Time
operation time).
Sets the value of the fan operation time monitor U4-03 in units
FanElapsTimeCn
of 10 h.
Sets the value of the Maintenance Monitor for the capacitors.
BusCap Maint Set
See U4-05 to check when the capacitors may need to be
replaced.
Sets the value of the Maintenance Monitor for the soft charge
ChrgCircMaintSet
bypass relay. See U4-06 to check when the bypass relay may
need to be replaced.
Sets the value of the Maintenance Monitor for the IGBTs. See
IGBT Maint Set
U4-07 for IGBT replacement times.
0: U2-oo and U3-oo monitor data is not reset when the drive
Fault Data Init
is initialized (A1-03).
0: No Reset
1: U2-oo and U3-oo monitor data is reset when the drive is
1: Reset
initialized (A1-03).
0: U4-10 and U4-11 monitor data is not reset when the drive is
kWh Monitor Init
initialized (A1-03).
0: No Reset
1: U4-10 and U4-11 monitor data is reset when the drive is
1: Reset
initialized (A1-03).
0: Number of Run commands counter is not reset when the drive
Run Counter Init
is initialized (A1-03).
0: No Reset
1: Number of Run commands counter is reset when the drive is
1: Reset
initialized (A1-03).
Date/Time Config
Sets the current date and time for the Real-Time Clock.
0: — —
0: - -
1: Set
1: Set
2: Reset
2: Reset
Time Disp Format
Sets the time display format.
0: 12-hour (AM/PM)
0: 12-hour
1: 24-hour
1: 24-hour
B.11 o: Operator Related Parameters
Description
Values
Page
Default: 0
Min.: 0
220
Max.: 9999
Default: 1
220
Range: 0, 1
Default: 0
Min.: 0
220
Max.: 9999
Default: 0%
Min.: 0
220
Max.: 150
Default: 0%
Min.: 0
221
Max.: 150
Default: 0%
Min.: 0
221
Max.: 150
Default: 0
221
Range: 0, 1
Default: 0
221
Range: 0, 1
Default: 0
221
Range: 0, 1
Default: 0
222
Range: 0 to 2
Default: 0
222
Range: 0, 1
B
355

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents