4.8 iQpump Presets and Functions
(P2-02) lower than the PID setpoint and set the Draw Down Level (P1-04) slightly above the PID setpoint to prevent
the drive from waking up until the water exceeds the desired depth setting. Sleeping helps the drive save energy and
mechanical wear. When P1-04 is set to 0 (default), the sleep function is disabled.
Related Parameters
No.
A1-01
Access Level Selection
A1-03
Initialize Parameters
E2-01
Motor Rated Current
E2-04
Number of Motor Poles
P1-03
Feedback Device Scaling
P1-11
High Feedback Level
P1-06
Minimum Pump Speed
P1-04
Start / Draw Down Level
P2-02
Sleep Level
P4-10
AUTO Mode Operator Run Power Down Storage
P5-02
HAND Speed Reference 1
P5-04
HAND Key Function Selection
Q1-01
PID Controller Setpoint 1
U1-99
Anti-No-Flow Timer
88
Parameter Name
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Setting Values
Default: 2
Range: 0 to 3
Default: 0
Range: 0 to 5550; 6008, 6009, 7770, 7771
Default: Depends on o2-04
Min.: 10% of drive rated current
Max.: 200% of drive rated current
Default: 2
Min.: 2
Max.: 48
Default: 145.0 PSI
Min.: 0.1
Max.: 6000.0
Default: 155.0 PSI
Min.: 0.0
Max.: 6000.0
Default: 40.0 Hz
Min.: 0.0
Max.: [E1-04]
Default: 0.0 PSI
Min.: -999.9
Max.: 999.9
Default: 0.0 Hz
Min.: 0.0
Max.: 6000.0
Default: 0
Range: 0, 1
Default: 40.0 Hz
Min.: 0
Max.: [E1-04]
Default: 1
Range: 0, 1
Default: 0.0
Min.: 0.0
Max.: 6000.0