B.11 o: Operator-Related Settings
B.11 o: Operator-Related Settings
The o parameters set up the digital operator displays.
u
o1: HOA Keypad Display Selection
No.
(Addr.
Name
Hex)
o1-01
Drive Mode Unit
(0500)
Monitor Selection
o1-02
User Monitor Selection
(0501)
after Power Up
o1-03
Digital Operator
(0502)
Display Selection
o1-05
(0504)
LCD Contrast Control
o1-06
User Monitor Selection
(0517)
Mode
o1-07
Second Line Monitor
(0518)
Selection
o1-08
Third Line Monitor
(0519)
Selection
o1-09
Frequency Reference
(051C)
Display Units
322
LCD Display
Selects the content of the last monitor that is shown when
scrolling through Drive Mode display. Enter the last three digits
User Monitor Sel
of the monitor parameter number to be displayed: Uo-oo.
Power-On Monitor
1: Frequency reference (U1-01)
1: Frequency Ref
2: Direction
2: FWD/REV
3: Output frequency (U1-02)
3: Output Freq
4: Output current (U1-03)
4: Output Current
5: User-selected monitor (set by o1-01)
5: User Monitor
Sets the units the drive should use to display the frequency
Display Unit Sel
reference and motor speed monitors.
0: 0.01 Hz
0: 0.01 Hz
1: 0.01%
1: 0.01% (100% = E1-04)
2: r/min
2: r/min (calculated using the number of motor poles setting in
3: User Units
E2-04)
3: User-selected units (set by o1-09, o1-10 and o1-11)
LCD Contrast
Sets the contrast of the LCD operator.
Selects the monitors displayed on the second and third lines of
Monitor Mode Sel
the digital operator display.
0: 3 Mon Sequential
0: 3 Monitor Sequential (displays the next two sequential
1: 3 Mon Selectable
monitors)
1: 3 Monitor Selectable (set by o1-07 and o1-08)
Selects the monitor that is shown in the second line.
Enter the last three digits of the monitor parameter number to
be displayed: Uo-oo. For example, set "403" to display
2nd Monitor Sel
monitor parameter U4-03.
Note:
Selects the monitor that is shown in the third line.
Enter the last three digits of the monitor parameter number to
be displayed: Uo-oo. For example, set "403" to display
3rd Monitor Sel
monitor parameter U4-03.
Note:
Fref Disp Unit
Sets unit display for the frequency reference parameters and
0: "WC:InchOfWater
frequency related monitors when o1-03 = 3.
1: PSI :lb/SqrInch
0: WC (Inch of water)
2: GPM:Gallons/Min
1: PSI (Pounds per square inch)
3: °F:DegFarenheit
2: GPM (Gallons per minute)
4: CFM:Cubic ft/Min
3: F (Degrees Fahrenheit)
5: CMH:Cubic m/Hr
4: CFM (Cubic feet per minute)
6: LPH:Litres/Hr
5: CMH (Cubic meters per hour)
7: LPS:Litres/Sec
6: LPH (Liters per hour)
8: Bar:Bar
7: LPS (Liters per second)
9: Pa:Pascals
8: Bar (Bar)
10: °C:DegCelsius
9: Pa (Pascal)
11: m: meters
10: C (Degrees Celsius)
12: ft: feet
11: Mtr (Meters)
12: Ft (Feet)
13: LPM:Litres/Min
14: CMM:Cubic M/
13: LPM (Liters per minute)
Min
14: CMM (Cubic meters per minute)
15: "Hg:Inch Mercury
15: "Hg (inches of mercury)
24: Custom Unit
24: Custom units (determined by o1-13 to o1-15)
25: No Unit
25: None
YASKAWA TOEPYAIUPW01A YASKAWA AC Drive - U1000 iQpump Matrix Drive User Manual
Description
Parameter is effective only
when o1-06 is set to 1.
Parameter is effective only
when o1-06 is set to 1.
Values
Page
Default: 106
(Monitor U1-06)
Range: 101 to
914
Default: 1
Range: 1 to 5
Default: 0
Range: 0 to 3
<1>
Default:
Range: 0, 1
Default: 1
Range: 0, 1
Default: 102
Range: 101 to
699
Default: 191
Range: 101 to
699
Default: 25
Range: 0 to 15;
24, 25