No.
(Addr.
Name
Hex)
Stall Prevention
L3-04
Selection during
(0492)
Deceleration
L3-05
Stall Prevention
(0493)
Selection during Run
L3-06
Stall Prevention Level
(0494)
during Run
Overvoltage
L3-11
Suppression Function
(04C7)
Selection
Target DC Bus Voltage
L3-17
for Overvoltage
(0462)
Suppression and Stall
Prevention
L3-20
DC Bus Voltage
(0465)
Adjustment Gain
L3-21
Accel/Decel Rate
(0466)
Calculation Gain
Automatic Reduction
L3-23
Selection for Stall
(04FD)
Prevention during Run
Motor Acceleration
L3-24
Time for Inertia
(046E)
Calculations
L3-25
Load Inertia Ratio
(046F)
<1> Upper limit is dependent on parameter L8-38, Frequency Reduction Selection.
<2> Default setting is dependent on parameter E1-01, Input voltage Setting.
<3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives.
<4> Parameter value changes automatically if E2-11 is manually changed or changed by Auto-Tuning.
<5> Default setting is dependent on parameter o2-04, Drive Model Selection.
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
LCD Display
0: Disabled. Deceleration at the active deceleration rate. An ov
fault may occur.
1: General purpose. Deceleration is paused when the DC bus
StallP Decel Sel
voltage exceeds the Stall Prevention level.
0: Disabled
2: Intelligent. Decelerate as fast as possible while avoiding ov
1: General purpose
faults.
2: Intelligent
3: Stall Prevention with braking resistor. Stall Prevention during
3: StallP +Resistor
deceleration is enabled in coordination with dynamic braking.
4: High Flux Brake
4: Overexcitation Deceleration. Decelerates while increasing
7: High Flux Brake3
the motor flux.
7: Overexcitation Deceleration 3. Applies more braking power
than normal overexcitation deceleration. Yaskawa recommends
extra caution due to the heavy load on the motor.
0: Disabled. Drive runs at a set frequency. A heavy load may
StallP Run Sel
cause speed loss.
0: Disabled
1: Decel time 1. Uses the deceleration time set to C1-02 while
1: Decel time
Stall Prevention is performed.
2: Decel time 2
2: Decel time 2. Uses the deceleration time set to C1-04 while
Stall Prevention is performed.
Enabled when L3-05 is set to 1 or 2. 100% is equal to the drive
rated current.
StallP Run Level
Enables or disables the ov suppression function, which allows
OV Inhibit Sel
the drive to change the output frequency as the load changes to
0: Disabled
prevent an ov fault.
1: Enabled
0: Disabled
1: Enabled
Sets the desired value for the DC bus voltage during overvoltage
suppression and Stall Prevention during deceleration.
DC Bus Reg Level
Sets the proportional gain for KEB Ride-Thru, Stall Prevention,
DC Bus P Gain
and overvoltage suppression.
Sets the proportional gain used to calculate the deceleration rate
Acc/Dec P Gain
during KEB Ride-Thru, ov suppression function, and Stall
Prevention during deceleration (L3-04 = 2).
0: Sets the Stall Prevention level set in L3-06 that is used
CHP Stall P Sel
throughout the entire frequency range.
0: Lv1 set in L3-06
1: Automatic Stall Prevention level reduction in the constant
1: Autom. Reduction
output range. The lower limit value is 40% of L3-06.
Sets the time needed to accelerate the uncoupled motor at rated
torque from stop to the maximum frequency.
Mtr Accel Time
Sets the ratio between the motor and machine inertia.
Load Inertia Rat
B.9 L: Protection Function
Description
Values
Page
Default: 0
199
Range: 0 to 4; 7
Default: 0
200
Range: 0 to 2
<1>
Default:
Min.: 30%
200
<1>
Max.: 150%
Default: 0
200
Range: 0, 1
Default: 375 Vdc
<2> <3>
200
Min.: 150
<3>
Max.: 400
Default: 1.00
Min.: 0.00
201
Max.: 5.00
Default: 1.00
Min.: 0.10
201
Max.: 10.00
Default: 0
201
Range: 0, 1
<4> <5>
Default:
202
Min: 0.001 s
Max: 10.000 s
Default: 1.0
202
Min.: 1.0
Max.: 1000.0
B
347