B.6 E: Motor Parameters
B.6 E: Motor Parameters
E1: V/f Pattern
u
No.
(Addr.
Name
Hex)
E1-01
Input Voltage Setting
(0300)
E1-03
V/f Pattern Selection
(0302)
330
LCD Display
This parameter must be set to the power supply voltage.
WARNING! Electrical Shock Hazard. Drive input voltage
(not motor voltage) must be set in E1-01 for the protective
Input Voltage
features of the drive to function properly. Failure to do so
may result in equipment damage and/or death or personal
injury.
V/F Selection
0: 50 Hz, Constant torque 1
0: 50 Hz
1: 60 Hz, Constant torque 2
1: 60 Hz Saturation
2: 60 Hz, Constant torque 3 (50 Hz base)
2: 60 Hz Saturation
3: 72 Hz, Constant torque 4 (60 Hz base)
3: 72 Hz
4: 50 Hz, Variable torque 1
4: 50 Hz VT1
5: 50 Hz, Variable torque 2
5: 50 Hz VT2
6: 60 Hz, Variable torque 3
6: 60 Hz VT1
7: 60 Hz, Variable torque 4
7: 60 Hz VT2
8: 50 Hz, High starting torque 1
8: 50 Hz HST1
9: 50 Hz, High starting torque 2
9: 50 Hz HST2
A: 60 Hz, High starting torque 3
A: 60 Hz HST1
B: 60 Hz, High starting torque 4
B: 60 Hz HST2
C: 90 Hz (60 Hz base)
C: 90 Hz
D: 120 Hz (60 Hz base)
D: 120 Hz
E: 180 Hz (60 Hz base)
E: 180 Hz
F: Custom V/f, E1-04 through E1-13 settings define the V/f
F: Custom V/F
pattern
Description
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Values
Page
Default: 230 V
<1>
155
Min.: 155
<1>
Max.: 255
<2>
Default: F
155
Range: 0 to 9;
A to FF