B.8 H Parameters: Multi-Function Terminals
No.
(Addr.
Name
Hex)
H5-12
Run Command Method
(043D)
Selection
<1> If this parameter is set to 0, the drive will be unable to respond to MEMOBUS/Modbus commands.
<2> When P1-01, Pump Mode, is set to 3 (MEMOBUS network), the range is dependent on P9-25, Highest Node Address.
H6: Pulse Train Input
u
No.
(Addr.
Name
Hex)
Pulse Train Input
H6-01
Terminal RP Function
(042C)
Selection
H6-02
(042D) Pulse Train Input
Scaling
H6-03
(042E)
Pulse Train Input Gain Term RP Gain
H6-04
(042F)
Pulse Train Input Bias
H6-05
Pulse Train Input Filter
(0430)
Time
H6-06
Pulse Train Monitor
(0431)
Terminal MP Selection
H6-07
Pulse Train Monitor
(0432)
Scaling
H6-08
Pulse Train Input
(043F)
Minimum Frequency
<1> When set for sourcing, +5 V/1.5 kΩ or higher, +8 V/3.5 kΩ or higher, +10 V/10 kΩ or higher. When set for sinking, the external power supply
should be +12 Vdc, ±5% with 16 mA or less.
344
LCD Display
Run CommandSel
0: FWD/Stop, REV/Stop
0: FWD Run &REV
1: Run/Stop, FWD/REV
Run
1: Run & FWD/REV
LCD Display
Term RP Func Sel
0: Frequency reference
0: Frequency Ref
1: PID feedback value
1: PID Feedback
2: PID setpoint value
2: PID Set Point
Sets the terminal RP input signal frequency that is equal to 100%
of the value selected in H6-01.
Term RP Scaling
Sets the level of the value selected in H6-01 when a frequency
with the value set in H6-02 is input.
Sets the level of the value selected in H6-01 when 0 Hz is input. Default: 0.0%
Term RP Bias
Sets the pulse train input filter time constant.
Term RP Flt Time
Select the pulse train monitor output function (value of the
o-oo part of Uo-oo).
Refer to U: Monitors on page 369
Term MP Func Sel
Example: Select "501" for monitor U5-01. Select "0" when not
using this parameter or when using in the through mode.
Sets the terminal MP output signal frequency when the monitor
value is 100%.
Term MP Scaling
Set H6-06 to 102 and H6-07 to 0 to make the pulse train monitor
output equal to the output frequency.
Sets the minimum frequency for the pulse train input to be
RP Lower Limit
detected. Enabled when H6-01 = 0, 1, or 2.
Description
Description
for the list of U monitors.
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Values
Page
Default: 0
394
Range: 0, 1
Values
Page
Default: 0
187
Range: 0 to 2
Default: 1440 Hz
187
Min.: 100
Max.: 32000
Default: 100.0%
187
Min.: 0.0
Max.: 1000.0
188
Min.: -100.0
Max.: 100.0
Default: 0.50 s
188
Min.: 0.00
Max.: 2.00
Default: 102
Range: 0, 31,
188
101, 102, 116,
501, 502,
<1>
Default: 1440 Hz
Min.: 0
188
Max.: 32000
Default: 0.5 Hz
188
Min.: 0.1
Max.: 1000.0