YASKAWA iQpump Micro CIMR-PW Series User Manual page 310

Ac drive compact intelligent pump controller
Table of Contents

Advertisement

A.1 Power Ratings
u
Three-Phase 400 V Class Drives
Item
Three-Phase Model
Maximum Applicable Motor Capacity kW (HP)
Input
Rated Output Capacity (kVA)
Output
Max Output Frequency (Hz)
Power Supply
Allowable Voltage Fluctuation
Harmonic Corrective
Actions
<1> The motor capacity (HP) refers to a NEC 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the
motor rated current.
<2> Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 460 V.
<4> DC is not available for UL standards.
Three-Phase Model
Maximum Applicable Motor Capacity kW (HP)
Input
Output
Power Supply
Allowable Frequency Fluctuation
Harmonic Corrective
Actions
<1> The motor capacity (HP) refers to a NEC 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the
motor rated current.
<2> Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 460 V.
<4> DC is not available for UL standards.
310
Table A.4 Three-Phase 400 V Class Power Ratings
<1>
<2>
Input Current (A)
<3>
Output Current (A)
Overload Tolerance
Carrier Frequency
Max Output Voltage (V)
Rated Voltage
Rated Frequency
Allowable Frequency
Fluctuation
DC Link Choke
Table A.5 Three-Phase 400 V Class Power Ratings Continued
Item
<1>
<2>
Input Current (A)
Rated Output Capacity (kVA)
<3>
Output Current (A)
Overload Tolerance
Carrier Frequency
Max Output Voltage (V)
Max Output Frequency (Hz)
Rated Voltage
Rated Frequency
Allowable Voltage Fluctuation
DC Link Choke
4V0002
4V0004
0.75 (1.0)
1.5 (2)
2.1
4.3
1.6
3.1
2.1
4.1
120% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
User-adjustable 2 to 15 kHz
Three-phase power: 380 to 480 V (proportional to input voltage)
400 Hz (user-adjustable)
Three-phase power: 380 to 480 V 50/60 Hz
DC power supply: 510 to 680 V
4V0011
4V0018
5.5 (7.5)
7.5 (10)
14.0
20.0
8.5
13.3
11.1
17.5
120% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
User-adjustable 2 to 15 kHz
Three-phase power: 380 to 480 V (proportional to input voltage)
400 Hz (user-adjustable)
Three-phase power: 380 to 480 V 50/60 Hz
DC power supply: 510 to 680 V
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Specification
4V0005
4V0007
2.2 (3)
3.0 (3)
5.9
8.1
4.1
5.3
5.4
6.9
<4>
-15 to 10%
±5%
Optional
Specification
4V0023
4V0031
11 (15)
15 (20)
24.0
38.0
17.5
23.6
23.0
31.0
<4>
-15 to 10%
±5%
Optional
4V0009
3.7 (5)
9.4
6.7
8.8
4V0038
18.5 (25)
44.0
29.0
38.0

Hide quick links: