3.5 Preparing IP66/NEMA 4X, UL Type 4X Enclosure Drives for Wiring
Route Cables Through Cable Glands
n
Route the cables through the cable glands then tighten the cable gland caps to complete preparation for main circuit and control
circuit wiring.
IP66/NEMA 4X, UL Type 4X Enclosure Front Cover Removal and Installation
u
NOTICE: Do not attempt to disassemble the protective enclosure surrounding the drive. The protective enclosure is constructed as a single
piece to include the heatsink. Attempting to disassemble the enclosure may void the protective integrity of the enclosure.
1.
Loosen the 4 bolts that attach the enclosure front cover in place, gently move the front cover away from the enclosure.
Refer to
Table 3.2
Press firmly on the digital operator cable connector release tab to disconnect the cable from port CN1 on the drive,
then remove the front cover.
Table 3.2 IP66/NEMA 4X, UL Type 4X Enclosure Front Cover Installation Bolt Size and Torque
Voltage Class
Single-Phase 200 V Class
Three-Phase 200 V Class
Three-Phase 400 V Class
48
Cable gland
(Locknut)
Cable gland
(Body)
Figure 3.12 Inserting the Cable Glands
Cable gland
(Locknut)
Cable gland
(Body)
Figure 3.13 Cable Routing
for installation bolt size.
Drive Model
BV0001G to BV0012G
2V0001G to 2V0020G
2V0030G to 2V0069G
4V0001G to 4V0011G
4V0018G to 4V0038G
Cable
Installation Bolt Size
M5
M5
M6
M5
M6
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Tightening Torque N•m (lb-in)
2.0 to 2.5 (17.7 to 22.1)
2.0 to 2.5 (17.7 to 22.1)
5.4 to 6.0 (47.8 to 53)
2.0 to 2.5 (17.7 to 22.1)
5.4 to 6.0 (47.8 to 53)