B.6 E: Motor Parameters
No.
(Addr.
Name
Hex)
E2-04
Number of Motor Poles Number of Poles
(0311)
E2-05
Motor Line-to-Line
(0312)
Resistance
E2-06
Motor Leakage
(0313)
Inductance
E2-10
Motor Iron Loss for
(0317)
Torque Compensation
E2-11
Motor Rated Power
(0318)
<1> Default setting is dependent on parameter o2-04, Drive Model Selection.
<2> Display is in the following units:
BV0006 to BV0018, 2V0006 to 2V0040, and 4V0002 to 4V0023: 0.01 A units.
2V0056 to 2V0069 and 4V0031 to 4V0038: 0.1 A units.
332
LCD Display
Sets the number of motor poles. Automatically set during
Auto-Tuning.
Sets the phase-to-phase motor resistance. Automatically set
during Auto-Tuning.
Term Resistance
Sets the voltage drop due to motor leakage inductance as a
percentage of motor rated voltage. Automatically set during
Leak Inductance
Auto-Tuning.
Sets the motor iron loss.
Motor Iron Loss
Sets the motor rated power in kilowatts (1 HP = 0.746 kW).
Automatically set during Auto-Tuning.
Mtr Rated Power
Description
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Values
Page
Default: 2
159
Min.: 2
Max.: 48
<1>
Default:
159
Min.: 0.000 Ω
Max.: 65.000 Ω
<1>
Default:
160
Min.: 0.0%
Max.: 40.0%
<1>
Default:
160
Min.: 0 W
Max.: 65535 W
<1>
Default:
Min.: 0.00 kW
160
Max.: 650.00
kW