O: Operator Related Parameters - YASKAWA iQpump Micro CIMR-PW Series User Manual

Ac drive compact intelligent pump controller
Table of Contents

Advertisement

B.11 o: Operator Related Parameters
o parameters set up the digital operator displays.
o1: HOA Keypad Display Selection
u
No.
(Addr.
Name
Hex)
o1-01
Drive Mode Unit
(0500)
Monitor Selection
o1-02
User Monitor Selection
(0501)
after Power Up
o1-03
Digital Operator
(0502)
Display Selection
o1-05
(0504)
LCD Contrast Control
o1-06
User Monitor Selection
(0517)
Mode
o1-07
Second Line Monitor
(0518)
Selection
o1-08
Third Line Monitor
(0519)
Selection
o1-09
Frequency Reference
(051C)
Display Units
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
LCD Display
Selects the content of the last monitor that is shown when
scrolling through Drive Mode display. Enter the last three digits
User Monitor Sel
of the monitor parameter number to be displayed: Uo-oo.
Power-On Monitor
1: Frequency reference (U1-01)
1: Frequency Ref
2: Direction
2: FWD/REV
3: Output frequency (U1-02)
3: Output Freq
4: Output current (U1-03)
4: Output Current
5: User-selected monitor (set by o1-01)
5: User Monitor
Sets the units the drive should use to display the frequency
Display Unit Sel
reference and motor speed monitors.
0: 0.01 Hz
0: 0.01 Hz
1: 0.01%
1: 0.01% (100% = E1-04)
2: r/min
2: r/min (calculated using the number of motor poles setting in
3: User Units
E2-04)
3: User-selected units (set by o1-09, o1-10 and o1-11)
LCD Contrast
Sets the brightness of the optional LCD operator.
Selects the monitors displayed on the second and third lines of
Monitor Mode Sel
the digital operator display.
0: 3 Mon Sequential
0: 3 Monitor Sequential (displays the next two sequential
1: 3 Mon Selectable
monitors)
1: 3 Monitor Selectable (set by o1-07 and o1-08)
Selects the monitor that is shown in the second line.
Enter the last three digits of the monitor parameter number to
be displayed: Uo-oo. For example, set "403" to display
2nd Monitor Sel
monitor parameter U4-03.
Note:
Selects the monitor that is shown in the third line.
Enter the last three digits of the monitor parameter number to
be displayed: Uo-oo. For example, set "403" to display
3rd Monitor Sel
monitor parameter U4-03.
Note:
Fref Disp Unit
Sets unit display for the frequency reference parameters and
0: "WC:InchOfWater
frequency related monitors when o1-03 = 3.
1: PSI :lb/SqrInch
0: WC (Inch of water)
2: GPM:Gallons/Min
1: PSI (Pounds per square inch)
3: °F:DegFarenheit
2: GPM (Gallons per minute)
4: CFM:Cubic ft/Min
3: F (Degrees Fahrenheit)
5: CMH:Cubic m/Hr
4: CFM (Cubic feet per minute)
6: LPH:Litres/Hr
5: CMH (Cubic meters per hour)
7: LPS:Litres/Sec
6: LPH (Liters per hour)
8: Bar:Bar
7: LPS (Liters per second)
9: Pa:Pascals
8: Bar (Bar)
10: °C:DegCelsius
9: Pa (Pascal)
11: m: meters
10: C (Degrees Celsius)
12: ft: feet
11: Mtr (Meters)
13: LPM:Litres/Min
12: Ft (Feet)
14: CMM:Cubic M/
13: LPM (Liters per minute)
Min
14: CMM (Cubic meters per minute)
15: "Hg:Inch Mercury
15: "Hg (inches of mercury)
25: No Unit
25: None
B.11 o: Operator Related Parameters
Description
Parameter is effective only
when o1-06 is set to 1.
Parameter is effective only
when o1-06 is set to 1.
Values
Page
Default: 106
(Monitor U1-06)
215
Range: 104 to
904
Default: 1
215
Range: 1 to 5
Default: 0
215
Range: 0 to 3
Default: 3
216
Range: 0 to 5
Default: 1
215
Range: 0, 1
Default: 102
Range: 101 to
215
904
Default: 191
215
Range: 101 to
904
Default: 25
Range: 0 to 15;
215
25
B
353

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents