A 7 E Motor Parameters - YASKAWA CIMR-ZU A Series Programming Manual

For hvac fan and pump, 200/400 v class: 2.2 to 110/370 kw 3 to 150/500 hp
Table of Contents

Advertisement

A 7 E Motor Parameters

E1
/ Pattern or Motor 1
No
(Addr
Name
e )
E1-01
Input Voltage Setting
(300)
E1-03
V/f Pattern Selection
(302)
E1-04
Maximum Output
(303)
Frequency
E1-05
Maximum Voltage
(304)
E1-06
Base Frequency
(305)
E1-07
Middle Output
(306)
Frequency
E1-08
Middle Output
(307)
Frequency Voltage
E1-09
Minimum Output
(308)
Frequency
E1-10
Minimum Output
(309)
Frequency Voltage
E1-11
Middle Output
(30A)
Frequency 2
<6>
E1-12
Middle Output
(30B)
Frequency Voltage 2
<6>
E1-13
Base Voltage
(30C)
LCD Display
This parameter must be set to the power supply voltage.
A NING Electrical Shock Hazard. Drive input voltage
(not motor voltage) must be set in E1-01 for the protective
Input Voltage
features of the drive to function properly. Failure to do so
may result in equipment damage and/or death or personal
injury.
V/F Selection
0: 50 Hz, Constant torque 1
0: 50 Hz
1: 60 Hz, Constant torque 2
1: 60 Hz Saturation
2: 60 Hz, Constant torque 3 (50 Hz base)
2: 60 Hz Saturation
3: 72 Hz, Constant torque 4 (60 Hz base)
3: 72 Hz
4: 50 Hz, Variable torque 1
4: 50 Hz VT1
5: 50 Hz, Variable torque 2
5: 50 Hz VT2
6: 60 Hz, Variable torque 3
6: 60 Hz VT1
7: 60 Hz, Variable torque 4
7: 60 Hz VT2
8: 50 Hz, High starting torque 1
8: 50 Hz HST1
9: 50 Hz, High starting torque 2
9: 50 Hz HST2
A: 60 Hz, High starting torque 3
A: 60 Hz HST1
B: 60 Hz, High starting torque 4
B: 60 Hz HST2
C: 90 Hz (60 Hz base)
C: 90 Hz
D: 120 Hz (60 Hz base)
D: 120 Hz
E: 180 Hz (60 Hz base)
E: 180 Hz
F: Custom V/f E1-04 through E1-13 settings define the V/f
F: Custom V/F
pattern
These parameters are only applicable when E1-03 is set to F.
To set linear V/f characteristics, set the same values for E1-07
Max Frequency
and E1-09.
In this case, the setting for E1-08 will be disregarded. Ensure
that the four frequencies are set according to these rules:
E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04
Max Voltage
Output Voltage (V)
Base Frequency
Mid Frequency A
Mid Voltage A
Min Frequency
Note:
Min Voltage
Mid Frequency B
Mid Voltage B
Base Voltage
Description
E1-05
E1-12
E1-13
E1-08
E1-10
E1-09
E1-07 E1-06 E1-11 E1-04
Frequency (Hz)
E1-07, E1-08, and E1-10 to E1-13 are not
available in OLV/PM control mode.
A 7 E Motor Parameters
alues
Pa e
Default: 230 V
<1>
64
Min.: 190
Max.: 240
<1>
Default: F
<2>
Range: 0 to 9;
64
A to F
Default:
<3> <4>
Min.: 40.0 Hz
67
Max.: 240.0 Hz
Default:
<3> <4>
Min.: 0.0 V
67
Max.: 255.0 V
<1>
Default:
<3> <4>
Min.: 0.0 Hz
67
Max.: 240.0 Hz
Default:
<3>
Min.: 0.0 Hz
67
Max.: 240.0 Hz
Default:
<3>
Min.: 0.0 V
67
Max.: 255.0 V
<1>
Default:
<3> <4>
Min.: 0.0 Hz
67
Max.: 240.0 Hz
Default:
<3>
Min.: 0.0 V
67
Max.: 255.0 V
<1>
Default: 0.0 Hz
Min.: 0.0
67
Max.: 240.0
Default: 0.0 V
Min.: 0.0
67
Max.: 255.0
<1>
Default: 0.0 V
<5>
67
Min.: 0.0
Max.: 255.0
<1>
227
A

Advertisement

Table of Contents
loading

This manual is also suitable for: