The tables below list all MEMOBUS/Modbus data.
The MEMOBUS register hex addresses for parameters are listed beginning on page 214.
Command Data
It is possible to both read and write command data.
Bits that are not used should be set to 0. Refrain from writing to reserved registers.
Note:
e ister No
0000H
Reserved
Operation Commands and Multi-function Inputs
bit 0
bit 1
bit 2
bit 3
bit 4
0001H
bit 5
bit 6
bit 7
bit 8
bit 9
0002H
Frequency Reference
0003H
V/f Gain
0004H, 0005H
Reserved
0006H
PI Target, 0.01% units, signed
0007H
Analog Output Terminal FM Setting (10 V / 4000 H)
0008H
Analog Output Terminal AM Setting (10 V / 4000 H)
Settings for Multi-Function Digital Outputs
bit 0
bit 1
bit 2
bit 3 to 5
bit 6
bit 7
bit 8 to F
000AH to 000CH
Reserved
000DH
PI2 Setpoint
000EH
Reserved
H5-12 = 0: Forward Run Command (0 = Stop, 1 = Forward Run)
H5-12 = 1: Run Command (0 = Stop, 1 = Run)
H5-12 = 0: Reverse Run Command (0 = Stop, 1 = Reverse Run)
H5-12 = 1: Forward/Reverse (0 = Forward, 1 = Reverse)
Fault Reset
Function is ComRef when H1-01 = 40 (Forward/Stop).
ComRef explanations.
Function is ComCtrl when H1-02 = 41 (Reverse/Stop).
ComCtrl explanations.
Multi-Function Input 4
Multi-Function Input 5
Multi-Function Input 6
Units are determined by parameter o1-03.
Multi-Function Contact Output 1 (terminal M1-M2)
Multi-Function Contact Output 2 (terminal M3-M4)
Multi-Function Contact Output 3 (terminal M5-M6)
Reserved
Enables the function in bit 7
Fault Contact Output (terminal MA/MB-MC)
Reserved