YASKAWA CIMR-ZU A Series Programming Manual page 264

For hvac fan and pump, 200/400 v class: 2.2 to 110/370 kw 3 to 150/500 hp
Table of Contents

Advertisement

A 1 U Monitors
No
(Addr
Name
e )
U1-12
Drive Status
(4B)
U1-13
Terminal A1 Input Level Term A1 Level
(4E)
U1-14
Terminal A2 Input Level Term A2 Level
(4F)
U1-16
Output Frequency after
(53)
Soft Starter
U1-18
oPE Fault Parameter
(61)
U1-19
MEMOBUS/Modbus
(66)
Error Code
U1-25
Software Number
(4D)
(Flash)
U1-26
Software No. (ROM)
(5B)
U1-27
Message ID (OPR)
(7A8)
U1-28
Message ID (INV)
(7A9)
<1> The number of decimal places in the parameter value depends on the drive model. This value has two decimal places (0.01 A) if the drive is set for
a maximum applicable motor capacity up to and including 11 kW, and one decimal place (0.1 A) if the maximum applicable motor capacity is
higher than 11 kW.
<2> When reading the value of this monitor via MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current.
<3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives.
<4> This value has two decimal places (0.01 kW) if the drive is set for a maximum applicable motor capacity up to and including 11 kW, and one
decimal place (0.1 kW) if the maximum applicable motor capacity is higher than 11 kW.
U2 Fault race
No
(Addr
Name
e )
U2-01
Current Fault
(80)
U2-02
Previous Fault
(81)
2
LCD Display
Verifies the drive operation status.
U1 - 12=
Int Ctl Sts 1
Displays the signal level to analog input terminal A1.
Displays the signal level to analog input terminal A2.
Displays output frequency with ramp time and S-curves. Units
SFS Output
determined by o1-03.
Displays the parameter number that caused the oPE
OPE Error Code
(EEPROM write error) error.
Displays the contents of a MEMOBUS/Modbus error.
U1 - 19=
Transmit Err
FLASH ID
CPU 1 SW Number
ROM ID
CPU 2 SW Number
OPR ID
MessageID (OPR)
INV ID
MessageID (INV)
LCD Display
Displays the current fault.
Current Fault
Displays the previous fault.
Last Fault
Description
00000000
1
During run
1
During zero-speed
1
During REV
1
During fault reset
signal input
1
During speed agree
1
Drive ready
1
During alarm
detection
1
During fault detection
00000000
1
CRC Error
1
Data Length Error
0
Not Used
1
Parity Error
1
Overrun Error
1
Framing Error
1
Timed Out
0
Not Used
Description
Analo
Unit
Output Le el
No signal output
available
10 V: 100%
0.1%
10 V: 100%
0.1%
10 V: Max
0.01 Hz
frequency
or Err
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
Analo
Unit
Output Le el
No signal output
available
No signal output
available

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z1000

Table of Contents