B Parameter List

◆ E: Motor Parameters

E1: V/f Pattern for Motor 1
No.
Name
E1-01
Input Voltage Setting
E1-03
V/f Pattern Selection
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-07
Middle Output Frequency
Middle Output Frequency
E1-08
Voltage
E1-09
Minimum Output Frequency
Minimum Output Frequency
E1-10
Voltage
E1-11
Middle Output Frequency 2
<21>
E1-12
Middle Output Frequency
Voltage 2
<21>
E1-13
Base Voltage
<3> Parameter setting value is not reset to the default value when the drive is initialized.
<4> Default setting is dependent on the control mode (A1-02), the drive model (o2-04), and the Drive Duty (C6-01).
<14> Default setting value is dependent on the motor code set to E5-01.
<18> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<21> Parameter ignored when E1-11 (Motor 1 Mid Output Frequency 2) and E1-12 (Motor 1 Mid Output Frequency Voltage 2) are set to 0.0.
<26> The setting range is 0.0 to 66.0 in AOLV/PM.
<27> When Auto-Tuning is performed, E1-13 and E1-05 will be set to the same value.
144
This parameter must be set to the power supply voltage.
WARNING! Drive input voltage (not motor voltage) must be set in E1-01 for
the protective features of the drive to function properly. Failure to do so may
result in equipment damage and/or death or personal injury.
0: 50 Hz, Constant torque 1
1: 60 Hz, Constant torque 2
2: 60 Hz, Constant torque 3 (50 Hz base)
3: 72 Hz, Constant torque 4 (60 Hz base)
4: 50 Hz, Variable torque 1
5: 50 Hz, Variable torque 2
6: 60 Hz, Variable torque 3
7: 60 Hz, Variable torque 4
8: 50 Hz, High starting torque 1
9: 50 Hz, High starting torque 2
A: 60 Hz, High starting torque 3
B: 60 Hz, High starting torque 4
C: 90 Hz (60 Hz base)
D: 120 Hz (60 Hz base)
E: 180 Hz (60 Hz base)
F: Custom V/f, E1-04 through E1-13 settings define the V/f pattern
These parameters are only applicable when E1-03 is set to F.
To set linear V/f characteristics, set the same values for E1-07 and E1-09. In this
case, the setting for E1-08 will be disregarded. Ensure that the four frequencies
are set according to these rules:
E1-09 ≤ E1-07 < E1-06 ≤ Ε1−11 ≤ E1-04
Note that if E1-11 = 0, then both E1-11 and E1-12 are disabled, and the above
conditions do not apply.
Output Voltage (V)
E1-05
E1-12
E1-13
E1-08
E1-10
Note: Some parameters may not be available depending on the control mode.
• E1-07, E1-08 and E-10 are available only in the following control modes: V/f
Control, V/f with PG, Open Loop Vector.
• E1-11, E1-12 and E-13 are available only in the following control modes: V/f
Control, V/f with PG, Open Loop Vector, Closed Loop Vector.
YASKAWA ELECTRIC TOEP C710616 21C YASKAWA AC Drive - A1000 Quick Start Guide
Description
E1-09
E1-07 E1-06 E1-11 E1-04
Frequency (Hz)
Setting
Default: 200 V
<18>
Min: 155 V
Max: 255 V
Default: F
<3>
Min: 0
Max: F
<30>
Default:
<4> <14>
Min: 40.0
Max: 400.0
<29>
Default:
<4> <14> <18>
Min: 0.00 V
Max: 255.0 V
<18>
Default:
<4> <14>
Min: 0.0
Max: E1-04
<29>
Default:
<4>
Min: 0.0
Max: E1-04
Default:
<4> <18>
Min: 0.0 V
Max: 255.0 V
<18>
Default:
<4> <14>
Min: 0.0
Max: E1-04
<26> <29>
Default:
<4> <18>
Min: 0.0 V
Max: 255.0 V
<18>
Default: 0.0 Hz
Min: 0.0
Max: E1-04
<26>
Default: 0.0 V
Min: 0.0 V
Max: 255.0 V
<18>
Default: 0.0 V
<18> <27>
Min: 0.0 V
Max: 255.0 V
<18>