Down Sequence Control; Pre-Fixing Arch Control - Canon imageRUNNER ADVANCE 715 series Service Manual

Table of Contents

Advertisement

Print Temperature Control
This is a control to set an optimal target temperature to prevent fixing error or high temperature offset. Temperature is controlled
to keep the specified target temperature during printing.
Setting the target temperature
A target temperature is determined according to the paper type/size, time which elapsed from when the last job finished, and
fixing temperature when startup control started.

Down Sequence Control

■ Down Sequence due to the Cartridge Temperature Rise
Purpose
To prevent the Drum Cleaning Blade from flipping when cartridge temperature rises during continuous paper feed
by estimating the temperature of the cartridge and enter down sequence.
Startup conditions
Enter down sequence stepwise according to the environment temperature and number of continuously printed sheets.
Environment temperature*1
32.5 deg C or more
28 to 32.5 deg C
Lower than 8.5 deg C
Environment temperature*1
32.5 deg C or more
28 to 32.5 deg C
Lower than 28 deg C
*1: It can be checked in the following service mode.
COPIER > DISPLAY > ANALOG > TEMP
*2: Not entering down sequence
*3: Inactive time is approximately 2 minutes
Operation
Prevent temperature rise of cartridge by reducing the speed to 1/2 speed or inactive+1/2 speed

Pre-fixing Arch Control

Purpose
To prevent the image on the drum to be affected from a shock which occurs when the trailing edge of the paper pulled by the
Fixing Drive passes through the Registration Roller by constantly creating an optimal arch between the transfer and fixing areas.
At 1-sided printing
1/2 speed
601 images or more
2251 images or more
At 2-sided printing
1/2 speed
251 to 500 images
501 to 1060 images
-
55
-
(1/2 speed)
501 images or more
1061 images or more
1001 images or more