E732-0010-00
Detection Description
Remedy
E732-0020-00
Detection Description
Remedy
E732-0021-00
Detection Description
Remedy
E732-0022-00
Detection Description
Remedy
E732-0023-04
Detection Description
Remedy
E732-0F01-04
Detection Description
Remedy
E732-0F20-00
Detection Description
Remedy
Communication error
A signal to start image transfer could not be detected at scanning although the specified period of
time (120 sec) has passed.
[Related parts] R1.00
- Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (J4001, 4002)
- READER ADF UNIT
- Main Controller PCB
[Remedy] Check/replace the related parts. After performing the remedy, check that the copy image
is output normally.
Communication error
A communication error of the Main Controller PCB was detected.
[Related parts] R1.00
- Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (J4001, 4002)
- READER ADF UNIT
- Main Controller PCB
[Remedy] Check/replace the related parts. After performing the remedy, check that the copy image
is output normally.
Communication error
A communication error between the Reader Controller PCB and the Main Controller PCB was
detected.
[Related parts] R1.00
- Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (J4001, 4002)
- READER ADF UNIT
- Main Controller PCB
[Remedy] Check/replace the related parts. After performing the remedy, check that the copy image
is output normally.
Communication error
A communication error between the Reader Controller PCB and the Main Controller PCB was
detected.
[Related parts] R1.00
- Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (J4001, 4002)
- READER ADF UNIT
- Main Controller PCB
[Remedy] Check/replace the related parts. After performing the remedy, check that the copy image
is output normally.
Communication error
DDI-S communication error (SPRDY-S detection error)
[Related parts] R1.00
- Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (J4001, 4002)
- READER ADF UNIT
- Main Controller PCB
[Remedy] Check/replace the related parts. After performing the remedy, check that the copy image
is output normally.
Communication error
Communication error that can be recovered by reboot
If it is detected again immediately after reboot, E732-0001 is generated.
It is not necessary to perform a remedy because the machine is automatically rebooted after log
collection.
Communication error
Communication error that can be recovered by reboot
If it is detected again immediately after reboot, E732-0020 is generated.
It is not necessary to perform a remedy because the machine is automatically rebooted after log
collection.