COPIER (Service mode for printer) > TEST (Print test mode) > NET-CAP
CAPSTATE
2
Detail
Adj/Set/Operate Method
Related Service Mode
Additional Functions
Mode
PONSTART
2
Detail
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Related Service Mode
Additional Functions
Mode
OVERWRIT
2
Detail
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Related Service Mode
Additional Functions
Mode
PAYLOAD
2
Detail
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Related Service Mode
Additional Functions
Mode
FILE-CLR
2
Detail
Adj/Set/Operate Method
SIMPFILT
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
State display of network packet capture
To display the state of network packet capture.
N/A (Display only)
COPIER> TEST> NET-CAP
Store Network Packet Log
Set network packet capture start timing
To set whether to perform network packet capture from power-on.
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: OFF, 1: ON
0
COPIER> TEST> NET-CAP
Store Network Packet Log
Setting of NetCap data overwriting
To set whether to finish network capturing or overwrite when HDD becomes full.
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: No overwriting (finish network packet capture), 1: Overwriting
1
COPIER> TEST> NET-CAP
Store Network Packet Log
Set network packet capture data save
To set whether to discard payload when saving the captured packet data.
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Save captured packet data as is, 1: Discard payload and save the packet data
0
COPIER> TEST> NET-CAP
Store Network Packet Log
Deletion of network packet capture data
To delete the captured packet data.
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Settings of packet data filtering
To set whether to perform filtering when capturing packet data.
When 0 is set, filtering is not performed (All the data are captured.)
When 1 is set, packet data is captured only when the receiver's or sender's address coincides with
the Mac address of this machine.
At problem analysis (at packet data analysis)
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Not filtered, 1: Filtered