Canon imageRUNNER ADVANCE 715 series Service Manual page 324

Table of Contents

Advertisement

E719-0041-00
Detection Description
Remedy
E719-0042-00
Detection Description
Remedy
E720-0001-00
Detection Description
Remedy
E730-C001-00
Detection Description
Remedy
E731-3000-00
Detection Description
Remedy
E731-3001-00
Detection Description
Remedy
E731-3002-00
Detection Description
Remedy
E731-3015-00
Detection Description
Remedy
E732-0001-04
Detection Description
Remedy
Coin vendor error
Communication with the coin vendor could not be established at startup of the host machine.
(Charge mode (COIN = 6) has been set.)
1. If it operates in charge mode (COIN = 6)
- Check that it is the supported charging management equipment.
- Check the cable to be connected.
- Check the power of the charging management equipment.
2. If charge mode is canceled
- Select COPIER> OPTION> ACC> COIN> "0", and turn OFF and then ON the main power.
Coin vendor error
Communication with the coin vendor could not be established at startup of the host machine.
(Charge mode (COIN = 6) has been set.)
1. If it operates in charge mode (COIN = 6)
- Check that it is the supported charging management equipment.
- Check the cable to be connected.
- Check the power of the charging management equipment.
2. If charge mode is canceled
- Select COPIER> OPTION> ACC> COIN> "0", and turn OFF and then ON the main power.
Error due to non-compatible Finisher
Non-compatible Finisher was connected.
Connect either the Staple Finisher-Y1 or Saddle Stitch Finisher-Y1.
Error in HDD access
An error occurred when accessing the HDD.
[Related parts] R1.00
- Harness between the Main Controller PCB and the HDD
- HDD
- Main Controller PCB
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Format the HDD and reinstall the system software using SST or a USB flash drive.
2. Check/replace the related harness/cable, connector and parts.
Main Controller PCB error
Unable to recognize the SURF Board.
Check/replace the Main Controller PCB
Main Controller PCB error
Failure of SURF initialization.
Check/replace the Main Controller PCB
Main Controller PCB error
Failure of SURF initialization.
Check/replace the Main Controller PCB
Main Controller PCB error
Video data is not transmitted to CL1-G even though there is no problem in the software.
Check/replace the Main Controller PCB
Communication error
DDI-S communication error.
[Related parts] R1.00
- Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (J4001, 4002)
- READER ADF UNIT
- Main Controller PCB
[Remedy] Check/replace the related parts. After performing the remedy, check that the copy image
is output normally.
314