Canon imageRUNNER ADVANCE 715 series Service Manual page 276

Table of Contents

Advertisement

NOTE:
If log collection is continued or setting change is repeated when an abnormality is found in operation of the function related to
debug logs, temporary files or log files may be remained in the machine. In that case, execute "DEFAULT" in service mode to
clear the settings related to debug logs and repeat the operation again.
Confirming the Existence of Debug Logs (HIT-STS)
This service mode confirms whether debug logs exist in the auto save area.
"OK!" is displayed if logs exist in the auto save area.
NOTE:
"OK!" is displayed even after pressing the Counter key + numeric keys 1, 2, and 3.
Initializing the Debug Log Settings (DEFAULT)
This service mode changes all the settings related to debug logs back to the default (settings at the time of shipment).
• Be sure to perform when returning the device to the customer after completion of trouble investigation. (Operations required)
• Execute this service mode when resetting the settings related to debug logs during investigation of log collection and perform
the operation again.
However, note that the log files automatically saved to the debug log save area in the controller are kept within the range not
exceeding the upper limit.
If you want to delete the saved logs (want to use HIT-STS), use "LOG-DEL" indicated later.
Deleting the Automatically Saved Log Files (LOG-DEL)
This service mode deletes the automatically saved and stored log files. The settings of log operation such as trigger for saving
log are not cleared.
Although it is not used normally (the upper limit of the number of saved logs is automatically controlled by firmware), it is necessary
to delete logs with LOG-DEL once when judging whether logs are collected using HIT-STS after changing the trigger for saving
log.
(It is because OK is displayed in HIT-STS as long as the saved logs exist.)