E614-0711-00
Detection Description
Remedy
E614-4000-00
Detection Description
Remedy
E614-4001-00
Detection Description
Remedy
E614-4002-00
Detection Description
Remedy
Error in file system on the Flash PCB
An error was detected in system setting value (service mode, etc.) storage area. (File could not
be written in the Flash PCB after startup or I/O error after startup)
[Related parts] R2.00
- Flash PCB
- Main Controller PCB
[Remedy] Perform the following in the order while checking whether the error is cleared. When
prioritizing clearing of the error, skip Remedies 2 and 3.
Although the error is cleared by "HD-CHECK", it may occur again. Thus, perform Remedies 1 to
4.
1. Check the related harness/cable and connector.
2. Select COPIER> FUNCTION> SYSTEM> CHK-TYPE> "8", and execute "HD-CHECK". Then,
turn OFF and then ON the main power.
3. Obtain the necessary backup data by referring to "Appendix> Backup Data List" in the System
Service Manual.
4. Select COPIER> FUNCTION> SYSTEM> CHK-TYPE> "8", and execute "HD-CLEAR". Then,
turn OFF and then ON the main power to delete the data in the corresponding partition.
5. Check/replace the related parts.
Error in system on the Flash PCB
The OS could not be recognized.
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
Perform the following in the order while checking whether the error is cleared.
1. After turning OFF the main power, remove and then install the Flash PCB again to check that
it is installed properly.
2. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
3. Check that the HDD and the cables are properly installed.
4. Enter safe mode using (2+8) startup, and format the HDD using SST or a USB flash drive.
5. If another error occurs, clear the error by performing the remedy for it.
6. Replace the Main Controller PCB.
Error in system on the Flash PCB
The OS boot file was not found.
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
Perform the following in the order while checking whether the error is cleared.
1. After turning OFF the main power, remove and then install the Flash PCB again to check that
it is installed properly.
2. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
3. Check that the HDD and the cables are properly installed.
4. Enter safe mode using (2+8) startup, and format the HDD using SST or a USB flash drive.
5. If another error occurs, clear the error by performing the remedy for it.
6. Replace the Main Controller PCB.
Error in system on the Flash PCB
The OS kernel was not found.
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
Perform the following in the order while checking whether the error is cleared.
1. After turning OFF the main power, remove and then install the Flash PCB again to check that
it is installed properly.
2. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
3. Check that the HDD and the cables are properly installed.
4. Enter safe mode using (2+8) startup, and format the HDD using SST or a USB flash drive.
5. If another error occurs, clear the error by performing the remedy for it.
6. Replace the Main Controller PCB.