Canon imageRUNNER ADVANCE 715 series Service Manual page 499

Table of Contents

Advertisement

COPIER (Service mode for printer) > OPTION (Specification setting mode) > USER
PCL-COPY
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
CNT-SW
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
BCNT-AST
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
PRJOB-CP
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Supplement/Memo
Set of PCL COPIES command control method
To set the binder control method of COPIES command with PCL.
Select whether to use the control method of Canon-made PCL or use the same control method of
non-Canon-made PCL.
Upon user's request
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 65535
0: Control method of Canon-made PCL (following the value of COPIES command that is specified
for each page to control on a page basis)
1: Control method of non-Canon-made PCL (handling the value of COPIES command, which is
specified for page 1 at the time of Collate mode, as bind figure while the value of COPIES command
for the next page or later is invalid. Same control applies as Canon-made PCL at the time of non-
sorted mode)
2 to 65535: For future use
0
Set default dspl items on charge counter
To set default display items of the charge counter on the Counter Check screen.
For details of each type, refer to the Service Manual.
Upon user's request
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Type1, 1: Type2
0
Set of box print charge target job
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set the job type that advances the count in box print with NE Controller (ASSIST).
When switching the job type that is subject to counting of the box print with NE Controller
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: PDL job, 1: Copy job
0
Set count TX at RX/report print
To set to enable/disable a page-basis count pulse transmission to the charging management
device at the time of reception print or report print.
Upon user's request
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: No transmission, 1: Transmission
0
Charging management device: Coin Manager, Non-Canon-made control card