Field Service Ver. 1.0 Apr. 2007
3.5
Maintenance procedure (periodical check parts)
NOTE
• The alcohol described in the cleaning procedure of maintenance represents the
isopropyl alcohol.
3.5.1
Cleaning of the original glass and original scanning glass
A. Periodically cleaning parts/cycle
• Original glass/original scanning glass: Every 80,000 prints
B. Procedure
[2]
3.5.2
Replacing the separation roller assy
A. Periodically replaced parts/cycle
• Separation roller assy: Every 150,000 prints
B. Procedure
1. Slide out the tray/1.
[1]
[2]
[1]
A09AF2C001DA
[1]
A09AF2C002DA
3. Periodical check
1. Using a soft cloth dampened with
alcohol, wipe the original glass [1]
and original scanning glass [2] clean
of dirt.
2. Remove two screws [1], and remove
the mounting bracket [2].
15