Allied Telesis AT-x510-28GTX Command Reference Manual page 664

Stackable gigabit edge switches
Hide thumbs Also See for AT-x510-28GTX:
Table of Contents

Advertisement

P
E
C
OWER OVER
THERNET
OMMANDS
-
SHOW POWER
INLINE COUNTERS
Table 2: Parameters in the show power-inline counters command output
Related
clear power-inline counters interface
Commands
show power-inline
show power-inline interface
C613-50102-01 REV C
Parameter
Description
Interface
The PoE port(s) in the format portx.y.z, where x is the device
number, y is the module number within the device, and z is the
PoE port number within the module.
MPSAbsent
The number of instances when the PoE MPS (Maintain Power
Signature) signal has been lost. The PoE MPS signal is lost when a
PD is disconnected from the PSE. Also increments
pethPsePortMPSAbsentCounter in the PoE MIB.
Overload
The number of instances when a PD exceeds its configured power
limit (as configured by the
increments pethPsePortOverLoadCounter in the PoE MIB.
Short
The number of short circuits that have happened with a PD. Also
increments pethPsePortShortCounter in the PoE MIB.
Invalid
The number of times a PD with an Invalid Signature (where the PD
has an open or short circuit, or is a legacy PD) is detected. Also
increments pethPseInvalidSignatureCounter in the PoE
MIB.
Denied
The number of times a PD has been refused power due to power
budget limitations for the PSE. Also increments
pethPsePortPowerDeniedCounter in the PoE MIB.
Command Reference for x510 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
power-inline max
command). Also