Status Changes:
Condition:
Alarm status:
Condition:
Alarm status:
Corrective Action:
acBoardCallResourcesAlarm Alarm Trap
Table 123
Alarm:
OID:
Default Severity:
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
Note:
Condition:
Alarm status:
acBoardControllerFailureAlarm Alarm Trap
Table 124
Alarm:
OID:
Default Severity:
Event Type:
Probable Cause:
®
3Com
VCX V7111 VoIP Gateway User Guide
When a soft reset is triggered using the Web interface or SNMP.
Critical
After raise
Status stays critical until reboot. A clear trap is not sent.
A network administrator has taken action to reset the device. No corrective
action is required.
acBoardCallResourcesAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.8
Major
processingErrorAlarm
softwareError (46)
Call resources alarm
Number of free channels exceeds the predefined RAI high threshold.
Major
To enable this alarm the RAI mechanism must be activated (EnableRAI = 1).
Number of free channels falls below the predefined RAI low threshold.
Cleared
acBoardControllerFailureAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.9
Minor
processingErrorAlarm
softwareError (46)
445