Component: Board#<N - 3Com VCX v7111 User Manual

Voip
Hide thumbs Also See for VCX v7111:
Table of Contents

Advertisement

Component: Board#<n>
The source varbind text for all the alarms under this component is Board#<n> where n is the
slot number. For V7111, <n> = 1.
acBoardFatalError Alarm Trap
Table 118
Alarm:
OID:
Default Severity:
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
<text> value:
Condition:
Alarm status:
Corrective Action:
442
acBoardFatalError
1.3.6.1.4.1.5003.9.10.1.21.2.0.1
Critical
equipmentAlarm
underlyingResourceUnavailable (56)
Board Fatal Error: <text>
Any fatal error
Critical
A run-time specific string describing the fatal error
After fatal error
Status stays critical until reboot. A clear trap is not sent.
Capture the alarm information and the Syslog clause, if active. Contact your
first-level support group. The support group will likely want to collect additional
data from the device and perform a reset.
®