<text value>:
Condition:
Alarm status:
Corrective Action:
acOperationalStateChange Alarm Trap
Table 121
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Note:
Status Changes:
Condition:
Alarm status:
Condition:
Alarm status:
Corrective Action:
acBoardEvResettingBoard Alarm Trap
Table 122
Alarm:
OID:
Default Severity:
Event Type:
Probable Cause:
Alarm Text:
444
Locked
Admin state changed to unlocked
Cleared
A network administrator has taken an action to lock the device. No corrective
action is required.
acOperationalStateChange
1.3.6.1.4.1.5003.9.10.1.21.2.0.15
Major
processingErrorAlarm
outOfService (71)
Network element operational state change alarm. Operational state is disabled.
This alarm is raised if the operational state of the node goes to disabled. The
alarm is cleared when the operational state of the node goes to enabled. In IP
systems, the operational state of the node is disabled if the device fails to properly
initialize.
Operational state changed to disabled
Major
Operational state changed to enabled
Cleared
In IP systems, check for initialization errors. Look for other alarms and Syslogs
that might provide additional information about the error.
acBoardEvResettingBoard
1.3.6.1.4.1.5003.9.10.1.21.2.0.5
critical
equipmentAlarm
outOfService (71)
User resetting board
®