3Com VCX v7111 User Manual page 443

Voip
Hide thumbs Also See for VCX v7111:
Table of Contents

Advertisement

acBoardTemperatureAlarm Alarm Trap
Table 119
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
Condition:
Alarm status:
Corrective Action:
acgwAdminStateChange Alarm Trap
Table 120
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
<text value>:
Condition:
Alarm status:
®
3Com
VCX V7111 VoIP Gateway User Guide
acBoardTemperatureAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.3
Critical
equipmentAlarm
temperatureUnacceptable (50)
Board temperature too high
Temperature is above 60 degrees C (140 degrees F)
Critical
After raise, temperature falls below 55 degrees C (131 degrees F)
Cleared
Inspect the system. Determine if all fans in the system are properly operating.
acgwAdminStateChange
1.3.6.1.4.1.5003.9.10.1.21.2.0.7
Major
processingErrorAlarm
outOfService (71)
Network element admin state change alarm Gateway is <text>
Admin state changed to shutting down
Major
Shutting down. No time limit.
Admin state changed to locked
Major
443

Advertisement

Table of Contents
loading

Table of Contents