RESOLVING PROBLEMS
If you have these symptoms...
The message
Switched-56 Network
appears. (continued)
not connected
You canÕt make or receive calls
and the red LED is on.
8-18
And this
network...
Switched-56
5. Run the Network Reflector
T1 or E1
1. Check that the T1 or E1 line is
2. Verify that you configured the T1
Do this...
Loopback test from the Loopback
Tests menu to determine if the
problem is with the network
interface board or the network
itself. Contact your network
provider to get a loopback number
you can call.
If the test indicates a defective
network interface board, contact
your PictureTel service provider.
If the test indicates a problem
with the network, contact your
network provider.
connected to the top port of the T1
or E1 network interface board.
or E1 network correctly. Check the
Set Data Rate and the Line
Configuration options in the T1 or
E1 network configuration menu.
Contact your
telecommunications department
for this information. Make sure
you donÕt change the settings
without their assistance.
If your conÞguration is correct
and the red LED stays on, contact
your network provider.